Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

10 September 2017 : Laboratory Research  

Modified Fan-Shaped Distribution Technology for Computed Tomography (CT)-Guided Radioactive Seed Implantation in Lung Cancer Patients with Lung Dysfunction

Peng Du1AB, Yueyong Xiao2CD, Wei Lu1EFG*

DOI: 10.12659/MSM.902105

Med Sci Monit 2017; 23:4366-4375

Abstract

BACKGROUND: The aim of this study was to investigate the safety and effectiveness of fan-shaped distribution and coaxial puncture technology for radioactive iodine 125 (125I) seed implantation in treatment of lung cancer patients with lung dysfunction.

MATERIAL AND METHODS: We enrolled and analyzed 33 lung cancer patients with lung dysfunction diagnosed in our hospital from 2013 to 2014 in this study, all of which were implanted with radioactive 125I seed with technology of fan-shaped distribution and coaxial puncture. The matched peripheral dose (MPD) range was 90–140GY. The brachytherapy planning system (TPS) was used to draw up a preoperative seed implantation plan. The fan-shaped distribution system was applied to simulate a surgery program, and seed implantation pitch was 0.5–1.0 cm. Real-time adjustment was necessary during surgery. Dose distributions were verified by TPS immediately after implantation. Intraoperative and postoperative surgery-related complications were analyzed. All patients were followed up for 6 months, and the local control rate of cancer was evaluated through CT scan.

RESULTS: All patients were operated on successfully. The main surgery-related complications were pulmonary hemorrhage, pleural cavity hemorrhage, and pneumothorax. The local control rates of 2-month, 4-month, and 6-month were 29%, 73%, and 85%, respectively. The total complete remission rate was 18%, the partial response rate was 67%, the stable disease rate was 12%, and the disease progression rate was 3%.

CONCLUSIONS: The fan-shaped distribution and coaxial puncture technology for radioactive 125I seed implantation was safe and effective in treating lung cancer patients with lung dysfunction.

Keywords: Biomedical Technology, Brachytherapy

Add Comment 0 Comments

Editorial

01 January 2026 : Editorial  

Editorial: Increasing Awareness of Lung Cancer in Non-Smokers and Never-Smokers Challenges Current Approaches to Prevention and Screening

Dinah V. Parums ORCID logo

DOI: 10.12659/MSM.952454

Med Sci Monit 2026; 32:e952454

0:00

In Press

Clinical Research  

Institutional and Regional Variations in Access to Clinical Trials and Next-Generation Sequencing in Turkis...

Med Sci Monit In Press; DOI: 10.12659/MSM.951027  

Clinical Research  

Low-Intensity Blood Flow-Restricted Multi-Joint Exercise Improves Muscle Function in Patients With Patellof...

Med Sci Monit In Press; DOI: 10.12659/MSM.950516  

Review article  

Musculoskeletal Ultrasound and MRI in the Evaluation of Chemotherapy-Induced Peripheral Neuropathy: A Review

Med Sci Monit In Press; DOI: 10.12659/MSM.951283  

Clinical Research  

Sensory Processing, Dissociation, and Affective Symptoms in Misophonia: A Cross-Sectional Study of 35 Adults

Med Sci Monit In Press; DOI: 10.12659/MSM.950938  

Most Viewed Current Articles

17 Jan 2024 : Review article   10,187,196

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,708,487

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,341,643

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   706,524

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750