Logo Medical Science Monitor

Call: +1.631.470.9640
Closed: National Holiday

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

16 November 2017 : Clinical Research  

Comparison of Treatment of Acute Unstable Distal Clavicle Fractures Using Anatomical Locking Plates with Versus without Additional Suture Anchor Fixation

Jixing Fan1BE, Yufu Zhang2CD, Qiang Huang2DF, Xieyuan Jiang2DF, Liang He2AG*

DOI: 10.12659/MSM.903440

Med Sci Monit 2017; 23:5455-5461

Abstract

BACKGROUND: Surgical managements were recommended for unstable distal clavicle fracture owing to the high incidence of nonunion. The present study compared the efficacy of anatomical locking plate with versus without additional suture anchor fixation for the treatment of unstable Neer type II distal clavicle fractures.

MATERIAL AND METHODS: Between January 2013 to January 2015, 28 consecutive patients with unstable Neer type II  fractures were treated by using anatomical locking plate with or without additional suture anchor fixation. The patients were divided into anatomical locking plate group (group A) and anatomical locking plate combined with suture anchor group (group B) according to the surgical method. The operative-related parameters such as operation time, blood loss, length of hospitalization, union time, functional outcomes (Constant score, UCLA score and DASH score) and CC distance were compared.

RESULTS: The mean follow-up period of the 28 patients was 19.60 months (21.80 versus 18.39 months, respectively). No statistical differences in general and peri-operative parameters were found between 2 groups. The group B had significant higher Constant score than group A (P=0.004, 91.67 versus 83.10). While no statistical differences were reached in the UCLA score and DASH score between 2 groups (P=0.112 and 0.163, respectively). The group A had longer CC distance than group B (11.67 versus 8.94 mm), while no statistic difference was found (P=0.067).

CONCLUSIONS: For the treatment of acute unstable Neer type II distal clavicle fractures, both surgical methods could offer satisfactory outcome. However, anatomical locking plate combined with additional suture anchor fixation had a better functional and radiographic outcome than that without additional suture anchor fixation.

Keywords: Bone Plates, Clavicle, Fracture Fixation

Add Comment 0 Comments

Editorial

01 January 2025 : Editorial  

Editorial: The Human Cell Atlas. What Is It and Where Could It Take Us?

Dinah V. Parums

DOI: 10.12659/MSM.947707

Med Sci Monit 2025; 31:e947707

0:00

In Press

Clinical Research  

Butorphanol Tartrate Nasal Spray for Post-Cesarean Analgesia and Prolactin Secretion

Med Sci Monit In Press; DOI: 10.12659/MSM.945224  

Database Analysis  

Role of the Carhart Effect and Outcomes from Surgery: A Retrospective Study of 532 Patients with Conductive...

Med Sci Monit In Press; DOI: 10.12659/MSM.947061  

Clinical Research  

Factors Affecting Medication Adherence in Middle-Aged and Elderly Patients in China: A Cross-Sectional Study

Med Sci Monit In Press; DOI: 10.12659/MSM.945805  

Review article  

Characteristics and Associated Risk Factors of Broad Ligament Hernia: A Systematic Review

Med Sci Monit In Press; DOI: 10.12659/MSM.946710  

Most Viewed Current Articles

17 Jan 2024 : Review article   6,963,278

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

16 May 2023 : Clinical Research   700,194

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

01 Mar 2024 : Editorial   23,571

Editorial: First Regulatory Approvals for CRISPR-Cas9 Therapeutic Gene Editing for Sickle Cell Disease and ...

DOI :10.12659/MSM.944204

Med Sci Monit 2024; 30:e944204

0:00

28 Jan 2024 : Review article   18,228

A Review of IgA Vasculitis (Henoch-Schönlein Purpura) Past, Present, and Future

DOI :10.12659/MSM.943912

Med Sci Monit 2024; 30:e943912

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750