16 December 2017 : Clinical Research  

Comparison of Accuracy of Pedicle Screw Insertion Among 4 Guided Technologies in Spine Surgery

Yong Fan1DF, Jinpeng Du12BCEF, Jianan Zhang1BD, Shichang Liu1BC, Xukai Xue1BC, Yunfei Huang1BD, Jing Zhang2AG, Dingjun Hao12AG

DOI: 10.12659/MSM.905713

Med Sci Monit 2017; 23:5960-5968

Abstract

BACKGROUND: As an available new tool for spinal surgery, robotic technology holds great potential and has been demonstrated to have better clinical outcomes compared with traditional techniques. However, it has not been compared with other assisted tools for the treatment of lumbar degenerative disease. This article focused on studying such variances.

MATERIAL AND METHODS: A total of 176 pedicle screws were inserted in 39 patients using a spine robot (group 1), 134 screws were implanted in 28 patients using navigational template (group 2), 234 screws were implanted in 51 patients by O-arm-based navigation (group 3), and 346 screws were implanted in 72 patients by fluoroscopy-guided assistance (group 4). The screw position was evaluated using postoperative scans according to Rampersaud A to D classification, and other secondary data were also collected.

RESULTS: “Perfect” pedicle screw insertion (Grade A) was 90.34%, 91.79%, 84.19%, and 65.03% of groups 1–4, respectively. “Clinically acceptable” screw implantation (Grade A+B) was 94.32%, 95.52, 90.60%, and 78.03% in groups 1–4, respectively. Deviation sagittal (°) respectively was 3±9, 2±10, 4±7, and 10±8° in groups 1–4, respectively. Deviation transversal (°) screw insertion was 3±8, 3±7, 4±9, and 8±13° in groups 1–4, respectively. Statistical analysis showed group 1 had no significant difference in the accuracy of “Perfect and Clinical acceptable” as well as deviation sagittal or transversal, respectively, compared with groups 2 and 3 but not group 4.

CONCLUSIONS: Robotic-assistance technology no clear advantage in terms of accuracy compared to the navigation template or O-arm systems for screw implantation, but it significantly reduced adverse events, fluoroscopy time per screw, postoperative stay, and blood loss.

Keywords: Bone Screws, Fluoroscopy, Robotics, Surgery, Computer-Assisted, Templates, Genetic

Add Comment 0 Comments

Editorial

01 July 2026 : Editorial  

Editorial: The WHO Identifies Ebola Disease Due to Bundibugyo Virus as a Public Health Emergency of International Concern (PHEIC) as Vaccine Development Accelerates

Dinah V. Parums ORCID logo

DOI: 10.12659/MSM.954627

Med Sci Monit 2026; 32:e954627

0:00

In Press

Clinical Research  

Body Weight and Insulin Resistance Indicators Among Children

Med Sci Monit In Press; DOI: 10.12659/MSM.951434  

Clinical Research  

Comparison of Radiographic Cervical Sagittal Alignment Parameters in Patients With Nonspecific Neck Pain, D...

Med Sci Monit In Press; DOI: 10.12659/MSM.952950  

Clinical Research  

Combined Fibrinogen and Urinary α1-Microglobulin as Predictors of Respiratory Tract Infection in Children w...

Med Sci Monit In Press; DOI: 10.12659/MSM.951066  

Database Analysis  

Evaluation of Salivary Total Oxidant Status (TOS) and Total Antioxidant Status (TAS) in Orthodontic Patient...

Med Sci Monit In Press; DOI: 10.12659/MSM.952052  

Most Viewed Current Articles

17 Jan 2024 : Review article   14,175,576

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,756,620

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,465,966

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   708,651

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750