BACKGROUND: The effects of focal hypertrophy on geometry of the left ventricle and systolic function have not been studied in patients with hypertrophic cardiomyopathy (HCM), despite the fact that the former is the most prominent disease characteristic. The aim of our study was to analyze systolic function over ventricle geometry, generating a functional index made from left ventricle end diastolic dimension (LVEDD) divided by end diastolic thickness of the region with maximal extent of hypertrophy and interventricular septum.

MATERIAL AND METHODS: Our hospital database of cardiac magnetic resonance was screened for HCM. Geometric functional index (GFI) was calculated for LVEDD over maximal end diastolic thickness (MaxEDT) giving GFI-M, while LVEDD over interventricular septum was expressed as GFI-I. There were 55 consecutive patients with HCM.

RESULTS: There were 43 males (78.2%) and 12 females (21.8%). The mean age was 52.3±16.7 years (range: 15.5–76.4 years). A significant difference of GFI was found for preserved versus impaired systolic function of the left ventricle (preserved systolic function); GFI-M 2.28±0.60 versus 3.66±0.50 (p<0.001), and GFI-I 2.75±0.88 versus 3.81±0.87 (p<0.001), respectively. Diagnostic value was tested using receiver operating curve (ROC) analyzes, with GFI-M area under curve (AUC)=0.959 (95% CI: 0.868–0.994); (p<0.001) and GFI-I-AUC=0.847 (0.724–0.930); (p<0.001). GFI-M was superior to GFI-I for appraisal of left ventricle systolic dysfunction in HCM; ΔAUC=0.112 (0.018–0.207); (p=0.020).

CONCLUSIONS: GFI is a simple tool, with high sensitivity and specificity for detecting impairment of systolic function in patients with HCM. Further studies would be necessary to investigate its clinical and prognostic impacts, as well as reproducibility with prospective validation.

Keywords: Cardiomyopathy, Hypertrophic, Heart Ventricles, Magnetic Resonance Imaging, Cine

Add Comment 0 Comments

Editorial

01 October 2024 : Editorial  

Editorial: Potentials and Pitfalls in Targeting Glucagon-Like Peptide-1 (GLP-1) in the Management of Increasing Levels of Obesity

Dinah V. Parums

DOI: 10.12659/MSM.946675

Med Sci Monit 2024; 30:e946675

0:00

In Press

Clinical Research  

Anterior Disc Displacement and Cortication Patterns in the Temporomandibular Joint

Med Sci Monit In Press; DOI: 10.12659/MSM.945967  

Review article  

Lamotrigine: A Safe and Effective Mood Stabilizer for Bipolar Disorder in Reproductive-Age Adults

Med Sci Monit In Press; DOI: 10.12659/MSM.945464  

Clinical Research  

Impact of Manual Sustained Inflation vs Stepwise PEEP on Pulmonary and Cerebral Outcomes in Carotid Endarte...

Med Sci Monit In Press; DOI: 10.12659/MSM.944936  

Clinical Research  

Predicting Vaginal Delivery Success: Role of Intrapartum Transperineal Ultrasound Angle of Descent at a Sin...

Med Sci Monit In Press; DOI: 10.12659/MSM.945458  

Most Viewed Current Articles

17 Jan 2024 : Review article   6,056,505

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

14 Dec 2022 : Clinical Research   1,846,289

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   693,590

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

07 Jan 2022 : Meta-Analysis   257,892

Efficacy and Safety of Light Therapy as a Home Treatment for Motor and Non-Motor Symptoms of Parkinson Dise...

DOI :10.12659/MSM.935074

Med Sci Monit 2022; 28:e935074

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750