Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

07 July 2018 : Laboratory Research  

Analysis of Base Monomer Elution from 3 Flowable Bulk-Fill Composite Resins Using High Performance Liquid Chromatography (HPLC)

Ryta Łagocka1ABDEF*, Małgorzata Mazurek-Mochol2EF, Katarzyna Jakubowska3AC, Maja Bendyk-Szeffer1F, Dariusz Chlubek3G, Jadwiga Buczkowska-Radlińska1G

DOI: 10.12659/MSM.907390

Med Sci Monit 2018; 24: LBR4679-4690

Abstract

BACKGROUND: The aim of this study was to evaluate the elution of BisGMA, UDMA, TEGDMA, and HEMA monomers from flowable bulk fill composite resins with different resin matrix compositions, polymerized in 4-mm-thick layers, into 3 elution media.

MATERIAL AND METHODS: Three bulk-fill (SDR® (SDR), X-tra base (XB) and BEAUTIFIL-Bulk Flowable (BF)) resin-composites were tested. Cylindrical samples were immersed in 100% ethanol, 75% ethanol, and distilled water. The concentrations of the monomers were measured using the HLPC method (Agilent Technologies 1200 Series) after 1 and 24 h, as well as after 3, 7, 14, and 21 days.

RESULTS: After polymerization of the tested resins, there was elution of the BisGMA, UDMA, TEGDMA, and HEMA monomers from the SDR and BF composites, but none of the tested monomers could be detected eluting from XB. The highest penetrations of the polymerized SDR and BF composites were observed in the 100% ethanol solution. This extraction medium eluted the highest amounts of free monomers. Some eluted monomers were not described in the composites Material Safety Data Sheets.

CONCLUSIONS: The elution of the residual monomers depended on the resin composition and the materials filler/resin matrix ratio. In composite materials, toxicity assessment should be carried out, and should consider both the material composition as given by the manufacturer, and also the residual monomers that elute from the polymerized material. The elution concentration and time of monomers from composites depended on the solvent used. The highest penetrations of the polymerized SDR and BF composites were observed in the 100% ethanol solution, and this extraction medium eluted the highest amounts of free monomers. The 75% ethanol was a more aggressive medium than water in terms of monomer elution from bulk fill composites.

Keywords: Chromatography, High Pressure Liquid, Composite Resins, Methylmethacrylate

Add Comment 0 Comments

Editorial

01 April 2024 : Editorial  

Editorial: Forty Years of Waiting for Prevention and Cure of HIV Infection – Ongoing Challenges and Hopes for Vaccine Development and Overcoming Antiretroviral Drug Resistance

Dinah V. Parums

DOI: 10.12659/MSM.944600

Med Sci Monit 2024; 30:e944600

0:00

In Press

05 Mar 2024 : Clinical Research  

Muscular Function Recovery from General Anesthesia in 132 Patients Undergoing Surgery with Acceleromyograph...

Med Sci Monit In Press; DOI: 10.12659/MSM.942780  

05 Mar 2024 : Clinical Research  

Effects of Thermal Insulation on Recovery and Comfort of Patients Undergoing Holmium Laser Lithotripsy

Med Sci Monit In Press; DOI: 10.12659/MSM.942836  

05 Mar 2024 : Clinical Research  

Role of Critical Shoulder Angle in Degenerative Type Rotator Cuff Tears: A Turkish Cohort Study

Med Sci Monit In Press; DOI: 10.12659/MSM.943703  

06 Mar 2024 : Clinical Research  

Comparison of Outcomes between Single-Level and Double-Level Corpectomy in Thoracolumbar Reconstruction: A ...

Med Sci Monit In Press; DOI: 10.12659/MSM.943797  

Most Viewed Current Articles

17 Jan 2024 : Review article  

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

14 Dec 2022 : Clinical Research  

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research  

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

01 Jan 2022 : Editorial  

Editorial: Current Status of Oral Antiviral Drug Treatments for SARS-CoV-2 Infection in Non-Hospitalized Pa...

DOI :10.12659/MSM.935952

Med Sci Monit 2022; 28:e935952

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750