Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

10 August 2018 : Clinical Research  

Comparison of Contrast-Enhanced Ultrasound and Positron Emission Tomography/Computed Tomography (PET/CT) in Lymphoma

Xiaoyan Niu1EF, Wenbin Jiang1EF, Xiaojuan Zhang1B, Zhaoyan Ding1B, Hongwei Xue2D, Zhenguang Wang3C, Cheng Zhao1A*

DOI: 10.12659/MSM.908849

Med Sci Monit 2018; 24: CLR5558-5565

Abstract

BACKGROUND: This study aimed to assess the value of contrast-enhanced ultrasound (CEUS) in the diagnosis and prognosis of lymphoma based on PET-CT.

MATERIAL AND METHODS: Our study included 88 superficial lymph nodes and 63 patients who underwent ultrasound-guided biopsy or surgery for pathology from October 2015 to March 2017. All lymph nodes were assessed by CEUS and PET-CT. CEUS and PET-CT parameters were recorded, including arrive time (AT), time to peak (TTP), base intensity (BI), peak intensity (PI), ascending slope (AS), descending slope (DS), area under the TIC curve (AUC), maximum standardized uptake value (SUVmax), and mean standardized uptake value (SUVmean). Pearson’s correlation was used to assess the associations of CEUS and PET-CT parameters.

RESULTS: Of the 88 lymph nodes examined,12 were Hodgkin’s lymphoma (HL) and76 were non-Hodgkin’s lymphoma (NHL). The variations of CEUS dose parameters (ΔI, AUC, and AS) were positively correlated with PET-CT results (SUVmax and TLG). Correlation coefficients were 0.609, 0.518, 0.456, 0.630, 0.593, and 0. 532, respectively. The remaining time values (AT, TP, and ΔT) were negatively associated with PET-CT results. Correlation coefficients were –0.239, –0.272, –0.284and –0.377, –0.391, and –0.320, respectively.

CONCLUSIONS: Quantitative CEUS data were correlated with PET-CT values, with potential use in the diagnosis of lymphoma.

Keywords: Evaluation Studies as Topic, Lymph Nodes, Positron-Emission Tomography, Ultrasonography

Add Comment 0 Comments

Editorial

01 November 2024 : Editorial  

Editorial: Artificial Intelligence (AI), Digital Image Analysis, and the Future of Cancer Diagnosis and Prognosis

Dinah V. Parums

DOI: 10.12659/MSM.947038

Med Sci Monit 2024; 30:e947038

0:00

In Press

Clinical Research  

Plaque Removal and Gingival Bleeding Using Biodegradable Toothbrushes: Salvadora persica, Bamboo, and Nylo...

Med Sci Monit In Press; DOI: 10.12659/MSM.944469  

0:00

Clinical Research  

Comparative Analysis of Extended Curettage with Plate Fixation and Extended Curettage with Intramedullary N...

Med Sci Monit In Press; DOI: 10.12659/MSM.945157  

Clinical Research  

Clinical Outcomes of Talus Bone Marrow Edema: Comparing Plaster Cast, Crutches, and Walking Boot Treatments

Med Sci Monit In Press; DOI: 10.12659/MSM.946072  

Review article  

Comprehensive Insights into Arecoline Hydrobromide: Pharmacology, Toxicity, and Pharmacokinetics

Med Sci Monit In Press; DOI: 10.12659/MSM.945582  

Most Viewed Current Articles

17 Jan 2024 : Review article   6,263,065

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

14 Dec 2022 : Clinical Research   1,908,785

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   695,294

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

07 Jan 2022 : Meta-Analysis   260,437

Efficacy and Safety of Light Therapy as a Home Treatment for Motor and Non-Motor Symptoms of Parkinson Dise...

DOI :10.12659/MSM.935074

Med Sci Monit 2022; 28:e935074

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750