28 June 2018 : Laboratory Research
Comparison of Load-Bearing Capacities of 3-Unit Fiber-Reinforced Composite Adhesive Bridges with Different Framework Designs
Ibrahim H. Tacir1ABF, Roda S. Dirihan2ABC, Zelal Seyfioglu Polat1AB, Gizem Ön Salman3BDE, Pekka Vallittu2ACEF, Lippo Lassila2ACDE, Emrah Ayna1E*DOI: 10.12659/MSM.909271
Med Sci Monit 2018; 24: LBR4440-4448
Abstract
BACKGROUND: The aim of this study was to investigate and compare the load-bearing capacities of three-unit direct resin-bonded fiber-reinforced composite fixed dental prosthesis with different framework designs.
MATERIAL AND METHODS: Sixty mandibular premolar and molar teeth without caries were collected and direct glass fiber-resin fixed FDPs were divided into 6 groups (n=10). Each group was restored via direct technique with different designs. In Group 1, the inlay-retained bridges formed 2 unidirectional FRC frameworks and pontic-reinforced transversal FRC. In Group 2, the inlay-retained bridges were supported by unidirectional lingual and occlusal FRC frameworks. Group 3, had buccal and lingual unidirectional FRC frameworks without the inlay cavities. Group 4 had reinforced inlay cavities and buccal-lingual FRC with unidirectional FRC frameworks. Group 5, had a circular form of fiber reinforcement around cusps in addition to buccal-lingual FRC frameworks. Group 6 had a circular form of fiber reinforcement around cusps with 2 bidirectional FRC frameworks into inlay cavities. All groups were loaded until final fracture using a universal testing machine at a crosshead speed of 1 mm/min.
RESULTS: Mean values of the groups were determined with ANOVA and Tukey HSD. When all data were evaluated, Group 6 had the highest load-bearing capacities and revealed significant differences from Group 3 and Group 4. Group 6 had the highest strain (p>0.05). When the fracture patterns were investigated, Group 6 had the durability to sustain fracture propagation within the restoration.
CONCLUSIONS: The efficiency of fiber reinforcement of the restorations alters not only the amount of fiber, but also the design of the restoration with fibers.
Keywords: Adhesives, Composite Resins, Light-Curing of Dental Adhesives
Editorial
01 January 2026 : Editorial
Editorial: Increasing Awareness of Lung Cancer in Non-Smokers and Never-Smokers Challenges Current Approaches to Prevention and ScreeningDOI: 10.12659/MSM.952454
Med Sci Monit 2026; 32:e952454
In Press
Clinical Research
Institutional and Regional Variations in Access to Clinical Trials and Next-Generation Sequencing in Turkis...Med Sci Monit In Press; DOI: 10.12659/MSM.951027
Clinical Research
Low-Intensity Blood Flow-Restricted Multi-Joint Exercise Improves Muscle Function in Patients With Patellof...Med Sci Monit In Press; DOI: 10.12659/MSM.950516
Review article
Musculoskeletal Ultrasound and MRI in the Evaluation of Chemotherapy-Induced Peripheral Neuropathy: A ReviewMed Sci Monit In Press; DOI: 10.12659/MSM.951283
Clinical Research
Sensory Processing, Dissociation, and Affective Symptoms in Misophonia: A Cross-Sectional Study of 35 AdultsMed Sci Monit In Press; DOI: 10.12659/MSM.950938
Most Viewed Current Articles
17 Jan 2024 : Review article 10,187,196
Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron VariantDOI :10.12659/MSM.942799
Med Sci Monit 2024; 30:e942799
13 Nov 2021 : Clinical Research 3,708,487
Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...DOI :10.12659/MSM.932788
Med Sci Monit 2021; 27:e932788
14 Dec 2022 : Clinical Research 2,341,643
Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase LevelsDOI :10.12659/MSM.937990
Med Sci Monit 2022; 28:e937990
16 May 2023 : Clinical Research 706,524
Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...DOI :10.12659/MSM.940387
Med Sci Monit 2023; 29:e940387