Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

20 January 2019 : Clinical Research  

A Usability Study of 3 Radiotherapy Systems: A Comparative Evaluation Based on Expert Evaluation and User Experience

Mingyin Jiang12ABCDEF, Shenglin Liu12AEFG, Jiaqi Gao12BC, Qingmin Feng12BC, Qiang Zhang12ACDEFG*

DOI: 10.12659/MSM.913160

Med Sci Monit 2019; 25:578-589

Abstract

BACKGROUND: The complex user interface design of radiotherapy treatment delivery systems can lead to use error and patient harm. In this study, we present the results of a comparison of 3 radiotherapy treatment delivery systems now used in China.

MATERIAL AND METHODS: We conducted a comprehensive usability study of 3 radiotherapy treatment delivery systems. Expert evaluation was performed through heuristic evaluation with 3 human-factors experts and 1 experienced radiation therapist for each system. User experience was assessed through perceived system usability and workload, using the National Aeronautics and Space Administration Task Load Index and the Post-Study System Usability Questionnaire.

RESULTS: For the expert evaluation, 47 usability problems were identified for Varian Trilogy, 75 for Elekta Precise, and 37 for Shinva XHA600E. Most problems were classified as major and minor usability problems, and were found in the process of patient setup and setup verification. For the user experience, radiation therapists presented a lower workload for Varian Trilogy compared to Elekta Precise (P<0.01) and Shinva XHA600E (P<0.01), and a lower workload for Elekta Precise compared to Shinva XHA600E (P=0.020). Radiation therapists perceived a higher system usability for Varian Trilogy compared to Shinva XHA600E (P<0.01), and a higher system usability for Elekta Precise compared to Shinva XHA600E (P<0.01).

CONCLUSIONS: This research provides valuable data on how 3 radiotherapy treatment delivery systems compare. The results of this study may be useful for hospital equipment procurement decisions, and designing next-generation products to improve patient safety.

Keywords: Equipment Design, Equipment Failure Analysis, Equipment Safety, Radiotherapy, User-Computer Interface, Patient safety, Patient Satisfaction, Surveys and Questionnaires

Add Comment 0 Comments

Editorial

01 January 2025 : Editorial  

Editorial: The Human Cell Atlas. What Is It and Where Could It Take Us?

Dinah V. Parums

DOI: 10.12659/MSM.947707

Med Sci Monit 2025; 31:e947707

0:00

In Press

Clinical Research  

Impact of Smovey Vibration Versus Dumbbell Resistance on Muscle Activation in Women

Med Sci Monit In Press; DOI: 10.12659/MSM.946567  

Clinical Research  

Five-Year Impact of Weight Loss on Knee Pain and Quality of Life in Obese Patients

Med Sci Monit In Press; DOI: 10.12659/MSM.946550  

Clinical Research  

Butorphanol Tartrate Nasal Spray for Post-Cesarean Analgesia and Prolactin Secretion

Med Sci Monit In Press; DOI: 10.12659/MSM.945224  

Database Analysis  

Role of the Carhart Effect and Outcomes from Surgery: A Retrospective Study of 532 Patients with Conductive...

Med Sci Monit In Press; DOI: 10.12659/MSM.947061  

Most Viewed Current Articles

17 Jan 2024 : Review article   6,963,045

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

16 May 2023 : Clinical Research   700,086

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

01 Mar 2024 : Editorial   23,449

Editorial: First Regulatory Approvals for CRISPR-Cas9 Therapeutic Gene Editing for Sickle Cell Disease and ...

DOI :10.12659/MSM.944204

Med Sci Monit 2024; 30:e944204

0:00

28 Jan 2024 : Review article   18,141

A Review of IgA Vasculitis (Henoch-Schönlein Purpura) Past, Present, and Future

DOI :10.12659/MSM.943912

Med Sci Monit 2024; 30:e943912

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750