Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

11 May 2019 : Meta-Analysis  

Diagnostic Performance of Perfusion Computed Tomography for Differentiating Lung Cancer from Benign Lesions: A Meta-Analysis

Cuiqing Huang12DE, Jianye Liang1BF, Xueping Lei3DF, Xi Xu1B, Zeyu Xiao1AC, Liangping Luo1A*

DOI: 10.12659/MSM.914206

Med Sci Monit 2019; 25:3485-3494

Abstract

BACKGROUND: Numerous studies have explored diagnosis of pulmonary nodules using perfusion computed tomography (CT); however, findings were not always consistent between studies. Th e present study aimed to summarize evidence on the diagnostic value of perfusion CT for distinguishing between lung cancer and benign lesions.

MATERIAL AND METHODS: We performed a systematic literature search on lung cancer and benign pulmonary lesions performed with perfusion CT. The searches were undertaken in English or Chinese language in Medline, PubMed, Embase, Cochrane Library, Web of Science, and China National Knowledge Infrastructure database from Jan 2010 to Nov 2018. Standardized mean differences (SMDs) and 95% confidence intervals (CIs) of blood volume (BV), blood flow (BF), mean transit time (MTT), and permeability surface (PS) were calculated using Review Manager 5.3. Publication bias, sensitivity, specificity, and the area under the curve (AUC) were calculated using Stata12.0.

RESULTS: Fourteen studies comprising 1032 malignant and 447 benign pulmonary lesions were analyzed. Lung cancer had higher BV, BF, MTT, and PS values than benign lesions. SMDs and 95% CIs of BV, BF, MTT, and PS were 2.29 (1.43, 3.16), 0.50 (0.14, 0.86), 0.55 (0.39, 0.72), and 1.21 (0.87, 1.56), respectively. AUC values of BV and PS were 0.92 (0.90, 0.94) and 0.83 (0.80, 0.86), respectively.

CONCLUSIONS: CT perfusion imaging is a valuable technique for the diagnosis of pulmonary nodules. Lung cancer had higher perfusion and permeability than benign lesions. The evidence suggests blood volume is the best surrogate marker for characterizing the blood supply, while permeability surface has a high specificity in quantifying the vascular permeability.

Keywords: Blood Volume, perfusion imaging, Permeability, Tomography, X-Ray, Aged, 80 and over, Area Under Curve, Perfusion, Publication Bias, Sensitivity and Specificity, Tomography, X-Ray Computed

Add Comment 0 Comments

Editorial

01 January 2026 : Editorial  

Editorial: Increasing Awareness of Lung Cancer in Non-Smokers and Never-Smokers Challenges Current Approaches to Prevention and Screening

Dinah V. Parums ORCID logo

DOI: 10.12659/MSM.952454

Med Sci Monit 2026; 32:e952454

0:00

In Press

Clinical Research  

Institutional and Regional Variations in Access to Clinical Trials and Next-Generation Sequencing in Turkis...

Med Sci Monit In Press; DOI: 10.12659/MSM.951027  

Clinical Research  

Low-Intensity Blood Flow-Restricted Multi-Joint Exercise Improves Muscle Function in Patients With Patellof...

Med Sci Monit In Press; DOI: 10.12659/MSM.950516  

Review article  

Musculoskeletal Ultrasound and MRI in the Evaluation of Chemotherapy-Induced Peripheral Neuropathy: A Review

Med Sci Monit In Press; DOI: 10.12659/MSM.951283  

Clinical Research  

Sensory Processing, Dissociation, and Affective Symptoms in Misophonia: A Cross-Sectional Study of 35 Adults

Med Sci Monit In Press; DOI: 10.12659/MSM.950938  

Most Viewed Current Articles

17 Jan 2024 : Review article   10,187,196

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,708,487

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,341,643

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   706,524

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750