Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

26 June 2019 : Laboratory Research  

Influence of Deviated Centers of Rotation on Kinematics and Kinetics of a Lumbar Functional Spinal Unit: An In Vitro Study

Shengzheng Kuai1234ABEF, Xinyu Guan5CEF, Yang Li5BC, Weiqiang Liu5AG, Yunfeng Xu6CD, Wenyu Zhou23ADG*

DOI: 10.12659/MSM.915614

Med Sci Monit 2019; 25:4751-4758

Abstract

BACKGROUND: Center of rotation (COR) has been used for assessing spinal motion quality. However, the biomechanical influence of COR deviation towards different directions during flexion-extension (FE) remains largely unknown. This study aimed to investigate the alteration in the range of motion (ROM), compressive force, shear force, and neutral zone size (NZ) in a lumbar functional spinal unit (FSU), caused by the deviated COR in different directions during FE.

MATERIAL AND METHODS: Twelve human cadaveric lumbar FSUs (6 for L2–L3, 6 for L4–L5) were tested in a 6-degree-of-freedom servo-hydraulic load frame. These FSUs were firstly applied a 7.5 Nm pure moment to perform FE to obtain their natural COR during FE. Subsequently, they were subjected to FE around 9 established deviated CORs with 6 Nm cyclical loading.

RESULTS: It was found that the ROM and NZ increased significantly when the COR moved from the superior plane to the inferior plane for the L2–L3 unit and when the COR located in the superior plane compared with the inferior plane for the L4–L5 unit. The compressive forces for both FSUs demonstrated significant changes caused by COR shift in the same horizontal plane, while the shear forces demonstrated significant changes caused by COR shift in the same vertical plane.

CONCLUSIONS: The ROM, NZ, and shear force of FSU are sensitive to the vertical COR shift, while the compressive force of FSU is highly sensitive to the horizontal COR shift. Additionally, the kinematics and kinetics of the L2–L3 unit are more sensitive to COR location than those of the L4–L5 unit.

Keywords: Biomechanical Phenomena, in vitro, Spine, Cadaver, Compressive Strength, Kinetics, Lumbar Vertebrae, Motion, Range of Motion, Articular, Rotation

Add Comment 0 Comments

Editorial

01 January 2026 : Editorial  

Editorial: Increasing Awareness of Lung Cancer in Non-Smokers and Never-Smokers Challenges Current Approaches to Prevention and Screening

Dinah V. Parums ORCID logo

DOI: 10.12659/MSM.952454

Med Sci Monit 2026; 32:e952454

0:00

In Press

Clinical Research  

Institutional and Regional Variations in Access to Clinical Trials and Next-Generation Sequencing in Turkis...

Med Sci Monit In Press; DOI: 10.12659/MSM.951027  

Clinical Research  

Low-Intensity Blood Flow-Restricted Multi-Joint Exercise Improves Muscle Function in Patients With Patellof...

Med Sci Monit In Press; DOI: 10.12659/MSM.950516  

Review article  

Musculoskeletal Ultrasound and MRI in the Evaluation of Chemotherapy-Induced Peripheral Neuropathy: A Review

Med Sci Monit In Press; DOI: 10.12659/MSM.951283  

Clinical Research  

Sensory Processing, Dissociation, and Affective Symptoms in Misophonia: A Cross-Sectional Study of 35 Adults

Med Sci Monit In Press; DOI: 10.12659/MSM.950938  

Most Viewed Current Articles

17 Jan 2024 : Review article   10,187,196

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,708,487

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,341,643

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   706,524

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750