Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

30 May 2019 : Clinical Research  

Analyzing Electroencephalography (EEG) Waves Provides a Reliable Tool to Assess the Depth of Sevoflurane Anesthesia in Pediatric Patients

Deepti Beekoo1ABCDEF, Kaiming Yuan1CDE, Shuyang Dai1BC, Lifen Chen1CD, Meiqin Di1BD, Sicong Wang1BF, Huacheng Liu2DF, Wangning ShangGuan1ABDEFG*

DOI: 10.12659/MSM.915640

Med Sci Monit 2019; 25:4035-4040

Abstract

BACKGROUND: Studies have reported that BIS is unreliable in children because its algorithm provides misleading information about the actual depth of anesthesia. Raw EEG analysis provides direct neurophysiologic measurement of cerebral activity. The relationship between age and EEG has rarely been reported, thus the aim of the present study was to compare raw electroencephalography (EEG) among different age groups of surgical patients under general anesthesia with 1.0 MAC sevoflurane.

MATERIAL AND METHODS: We enrolled 135 patients aged 0–80 years old (ASA physical status I or II) undergoing surgery, who were divided into 6 groups: 1–12 months old (group 1), 1–3 years old (group 2), 3–6 years old (group 3), 6–18 years old (group 4), 18–65 years old (group 5), and 65–80 years old (group 6). Different raw EEG waves (alpha, delta, and theta) were compared for all subjects.

RESULTS: The BIS values in groups 1 to 6 were 52.2±12.7, 55.0±8.0, 44.5±7.3, 43.8±7.3, 44.2±6.2, and 49.1±6.2 respectively. Compared with groups 1 and 2 (52.2±12.7, 55.0±8.0), BIS values of groups 3, 4, and 5 (44.5±7.3, 43.8±7.3, 44.2±6.2, respectively) were lower (P<0.05). Theta frequency was observed in the 6 groups. The EEG frequencies in groups 1 to 6 were 6.0 (5.5–6.0), 6.0 (5.5–6.0), 6.0 (5.5–6.0), 6.0 (6.0–7.0), 6.3 (6.0–7.0), and 6.0 (5.1–6.0), respectively. Compared with group 6, EEG frequencies in groups 4 and 5 were higher (P<0.05). BIS value was significantly correlated with EEG frequency (R²=0.063, P<0.01).

CONCLUSIONS: Analyzing raw EEG waves provides more accurate judgement of depth of anesthesia, especially in pediatric cases in which monitors often provide misleading values.

Keywords: Age Groups, Consciousness Monitors, Electroencephalography, Adolescent, Aged, 80 and over, Anesthesia, General, Child, Child, Preschool, Heart Rate, Infant, Monitoring, Intraoperative, Monitoring, Physiologic

Add Comment 0 Comments

Editorial

01 July 2026 : Editorial  

Editorial: The WHO Identifies Ebola Disease Due to Bundibugyo Virus as a Public Health Emergency of International Concern (PHEIC) as Vaccine Development Accelerates

Dinah V. Parums ORCID logo

DOI: 10.12659/MSM.954627

Med Sci Monit 2026; 32:e954627

0:00

In Press

Clinical Research  

Analysis of the Clinical Characteristics and Endoscopic Features of Phytobezoar-Induced Ulcers and Gastric ...

Med Sci Monit In Press; DOI: 10.12659/MSM.952191  

Clinical Research  

Effect of Indirect Co-Culture With Gingival Mesenchymal Stem Cells on Cytokine Secretion in Primary Oral Sq...

Med Sci Monit In Press; DOI: 10.12659/MSM.952439  

Clinical Research  

Comparison of Sleep Architecture in Individuals Aged 65 to 80 Years With and Without Mild Cognitive Impairm...

Med Sci Monit In Press; DOI: 10.12659/MSM.952493  

Clinical Research  

Effects of Single-Bout Endurance Exercise Intensity on Peripheral Neurotrophic Factors in Patients With Isc...

Med Sci Monit In Press; DOI: 10.12659/MSM.952089  

Most Viewed Current Articles

17 Jan 2024 : Review article   14,176,514

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,760,677

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,466,264

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   708,906

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750