Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

13 September 2019 : Clinical Research  

Ankle Joint Position and the Reliability of Ultrasound Tissue Characterization of the Achilles Tendon: A Pilot Study

Arturo Lawson1ABCDEF*, Marika Noorkoiv1BE, Lorenzo Masci2BDE, Amir A. Mohagheghi1E

DOI: 10.12659/MSM.915685

Med Sci Monit 2019; 25:6884-6893

Abstract

BACKGROUND: Imaging of the Achilles tendon using ultrasound tissue characterization (UTC) involves taking up the slack of the tendon by including dorsiflexion of the ankle. This pilot study aimed to determine whether different longitudinal tension applied to the Achilles tendon during imaging affected the reliability of UTC.

MATERIAL AND METHODS: Nine asymptomatic active volunteers, aged between 23–49 years underwent imaging of 17 Achilles tendons. Three positions of tension included plantar grade, 50%, and 100% of maximal dorsiflexion, with a range of 18–32°. Ranges were established and standardized using an isokinetic dynamometer. A test and re-test process was conducted at each position to determine the intraclass correlation coefficients (ICCs) and minimum detectable change (MDC) per echotype. Images were analyzed using UTC software.

RESULTS: Plantar grade positioning images could not be obtained. ICCs for each echotype I–IV between test 1 and test 2 were 0.965, 0.962, 0.858, 0.739 at 100% dorsiflexion (95% CI, 0.86–0.99, 0.84–0.99, 0.51–0.97, and 0.2–0.94), and 0.771, 0.551, 0.569, 0.429 at 50% dorsiflexion (95% CI, 0.29–0.94, –0.09–0.88, –0.01–0.88, and –0.15–0.82). The MDC per echotype I–IV ranged between 4.1–1.0% of echotype data at 100% dorsiflexion, and 17.2–6.3% at 50% dorsiflexion.

CONCLUSIONS: Testing at maximum dorsiflexion provided improved reliability when using UTC in healthy individuals. The ICC at 100% dorsiflexion was increased, and the MDC was reduced for all echotypes. Therefore, standardizing test positions when using UTC is advisable for reliable comparison of results between studies.

Keywords: Achilles Tendon, Reproducibility of Results, Tendinopathy, Ultrasonography, Ankle Joint, Image Processing, Computer-Assisted, Pilot Projects

Add Comment 0 Comments

Editorial

01 December 2024 : Editorial  

Editorial: The 2024 Revision of the Declaration of Helsinki and its Continued Role as a Code of Ethics to Guide Medical Research

Dinah V. Parums

DOI: 10.12659/MSM.947428

Med Sci Monit 2024; 30:e947428

0:00

In Press

Clinical Research  

Shiga Toxin-Producing E. coli and Hemolytic Uremic Syndrome: A Study of the 2022 Outbreak in Turkey

Med Sci Monit In Press; DOI: 10.12659/MSM.946033  

Clinical Research  

Evaluating Lipiodol Efficacy in Proximal Tubal Occlusion Treatment: Single-Center Experience and Literature...

Med Sci Monit In Press; DOI: 10.12659/MSM.946266  

Review article  

Impact of Traditional Chinese Medicine Antioxidants on Oxidative Stress and Drug-Induced Liver Injury: A Re...

Med Sci Monit In Press; DOI: 10.12659/MSM.945147  

Meta-Analysis  

Reliability of Extraoral Scanners in Capturing 3D Geometry for Dental Prostheses: A Systematic Review

Med Sci Monit In Press; DOI: 10.12659/MSM.946470  

Most Viewed Current Articles

17 Jan 2024 : Review article   6,956,909

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

14 Dec 2022 : Clinical Research   1,969,236

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   696,965

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

07 Jan 2022 : Meta-Analysis   263,014

Efficacy and Safety of Light Therapy as a Home Treatment for Motor and Non-Motor Symptoms of Parkinson Dise...

DOI :10.12659/MSM.935074

Med Sci Monit 2022; 28:e935074

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750