Abstract
BACKGROUND: Imaging of the Achilles tendon using ultrasound tissue characterization (UTC) involves taking up the slack of the tendon by including dorsiflexion of the ankle. This pilot study aimed to determine whether different longitudinal tension applied to the Achilles tendon during imaging affected the reliability of UTC.
MATERIAL AND METHODS: Nine asymptomatic active volunteers, aged between 23–49 years underwent imaging of 17 Achilles tendons. Three positions of tension included plantar grade, 50%, and 100% of maximal dorsiflexion, with a range of 18–32°. Ranges were established and standardized using an isokinetic dynamometer. A test and re-test process was conducted at each position to determine the intraclass correlation coefficients (ICCs) and minimum detectable change (MDC) per echotype. Images were analyzed using UTC software.
RESULTS: Plantar grade positioning images could not be obtained. ICCs for each echotype I–IV between test 1 and test 2 were 0.965, 0.962, 0.858, 0.739 at 100% dorsiflexion (95% CI, 0.86–0.99, 0.84–0.99, 0.51–0.97, and 0.2–0.94), and 0.771, 0.551, 0.569, 0.429 at 50% dorsiflexion (95% CI, 0.29–0.94, –0.09–0.88, –0.01–0.88, and –0.15–0.82). The MDC per echotype I–IV ranged between 4.1–1.0% of echotype data at 100% dorsiflexion, and 17.2–6.3% at 50% dorsiflexion.
CONCLUSIONS: Testing at maximum dorsiflexion provided improved reliability when using UTC in healthy individuals. The ICC at 100% dorsiflexion was increased, and the MDC was reduced for all echotypes. Therefore, standardizing test positions when using UTC is advisable for reliable comparison of results between studies.
Keywords: Achilles Tendon, Reproducibility of Results, Tendinopathy, Ultrasonography, Ankle Joint, Image Processing, Computer-Assisted, Pilot Projects
Editorial
01 December 2024 : Editorial
Editorial: The 2024 Revision of the Declaration of Helsinki and its Continued Role as a Code of Ethics to Guide Medical ResearchDOI: 10.12659/MSM.947428
Med Sci Monit 2024; 30:e947428
In Press
Clinical Research
Shiga Toxin-Producing E. coli and Hemolytic Uremic Syndrome: A Study of the 2022 Outbreak in TurkeyMed Sci Monit In Press; DOI: 10.12659/MSM.946033
Clinical Research
Evaluating Lipiodol Efficacy in Proximal Tubal Occlusion Treatment: Single-Center Experience and Literature...Med Sci Monit In Press; DOI: 10.12659/MSM.946266
Review article
Impact of Traditional Chinese Medicine Antioxidants on Oxidative Stress and Drug-Induced Liver Injury: A Re...Med Sci Monit In Press; DOI: 10.12659/MSM.945147
Meta-Analysis
Reliability of Extraoral Scanners in Capturing 3D Geometry for Dental Prostheses: A Systematic ReviewMed Sci Monit In Press; DOI: 10.12659/MSM.946470
Most Viewed Current Articles
17 Jan 2024 : Review article 6,956,909
Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron VariantDOI :10.12659/MSM.942799
Med Sci Monit 2024; 30:e942799
14 Dec 2022 : Clinical Research 1,969,236
Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase LevelsDOI :10.12659/MSM.937990
Med Sci Monit 2022; 28:e937990
16 May 2023 : Clinical Research 696,965
Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...DOI :10.12659/MSM.940387
Med Sci Monit 2023; 29:e940387
07 Jan 2022 : Meta-Analysis 263,014
Efficacy and Safety of Light Therapy as a Home Treatment for Motor and Non-Motor Symptoms of Parkinson Dise...DOI :10.12659/MSM.935074
Med Sci Monit 2022; 28:e935074