Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

10 August 2019 : Clinical Research  

Acetabular Lateral View: Effective Fluoroscopic Imaging to Evaluate Screw Penetration Intraoperatively

Zhe Lin1BC, Jialiang Guo123EG*, Weichong Dong4DF, Kuo Zhao123F, Zhiyong Hou12A, Yingze Zhang1235AB

DOI: 10.12659/MSM.915906

Med Sci Monit 2019; 25:5953-5960

Abstract

BACKGROUND: Screw penetration into the hip joint is a severe complication during acetabular fracture surgery. The standard fluoroscopic views of the pelvis cannot provide adequate safety during screw insertion. The aim of this research was to determine and evaluate the accuracy of the acetabular lateral view for screw placement.

MATERIAL AND METHODS: Twenty screws were randomly chosen and intentionally penetrated into the articular surface (1–2 mm), and the remaining 20 screws were extra-articular ones positioned in close proximity to the articular surface. Three surgeons, each evaluating 40 screws, provided a total of 120 rated observations for each screw position. We compared the traditional view or combined with lateral acetabular view with the criterion standard based on unaided visual assessment. A blinded and independent review of each pelvic intraoperative fluoroscopy was made by 3 independent observers. Specificity, sensitivity, positive predictive value, negative predictive value, correct interpretation, intra-class correlation coefficients (ICC), and Youden index were calculated.

RESULTS: There were significant differences in sensitivity, NPV, correct interpretation, and Youden index between the 2 groups (P<0.05). The ICC was 0.531 when the antero-posterior, iliac, and obturator oblique views were used. The ICC was remarkably increased when using a combination of the ‘‘lateral’’ view and the standard views for screw perforation of the joint.

CONCLUSIONS: Use of the lateral view of the acetabulum can be a complementary method to identify malpositioned screws, and it helps increase the accuracy rate of inserting screws in the treatment of posterior wall fracture.

Keywords: Acetabularia, Bone Screws, Radiography, Acetabulum, Cadaver, Fluoroscopy, Fracture Fixation, Internal, Fractures, Bone, Hip Fractures, Pelvis, Surgery, Computer-Assisted

Add Comment 0 Comments

Editorial

01 January 2026 : Editorial  

Editorial: Increasing Awareness of Lung Cancer in Non-Smokers and Never-Smokers Challenges Current Approaches to Prevention and Screening

Dinah V. Parums ORCID logo

DOI: 10.12659/MSM.952454

Med Sci Monit 2026; 32:e952454

0:00

In Press

Clinical Research  

Institutional and Regional Variations in Access to Clinical Trials and Next-Generation Sequencing in Turkis...

Med Sci Monit In Press; DOI: 10.12659/MSM.951027  

Clinical Research  

Low-Intensity Blood Flow-Restricted Multi-Joint Exercise Improves Muscle Function in Patients With Patellof...

Med Sci Monit In Press; DOI: 10.12659/MSM.950516  

Review article  

Musculoskeletal Ultrasound and MRI in the Evaluation of Chemotherapy-Induced Peripheral Neuropathy: A Review

Med Sci Monit In Press; DOI: 10.12659/MSM.951283  

Clinical Research  

Sensory Processing, Dissociation, and Affective Symptoms in Misophonia: A Cross-Sectional Study of 35 Adults

Med Sci Monit In Press; DOI: 10.12659/MSM.950938  

Most Viewed Current Articles

17 Jan 2024 : Review article   10,187,196

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,708,487

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,341,643

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   706,524

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750