26 December 2019 : Clinical Research
A Comparative Study of C2 Pedicle or Pars Screw Placement with Assistance from a 3-Dimensional (3D)-Printed Navigation Template versus C-Arm Based Navigation
Ye Tian1AB, Jianan Zhang1CD, Tuanjiang Liu1F, Shi Tang2E, Hao Chen1C, Keyuan Ding1F, Dingjun Hao1FG*DOI: 10.12659/MSM.918440
Med Sci Monit 2019; 25:9981-9990
Abstract
BACKGROUND: Since C2 is adjacent to important nerves and blood vessels, the implantation risk of C2 internal fixation in this area is high and requires high accuracy. This study mainly discussed the application value of 3-dimensional (3D)-printed navigation template in C2 screw placement.
MATERIAL AND METHODS: A retrospective study compared 3D-printed navigation template-assisted screw placement (group A, n=32) and the C-arm based navigation-assisted screw placement group (group B, n=32). Group A was divided into 2 subgroups: A1 (C2 pedicle screw placement) and A2 (C2 pars screw placement); group B was divided into B1 (C2 pedicle screw placement) and B2 (C2 pars screw placement). The accuracy and safety of screw placement and clinical outcomes were evaluated.
RESULTS: There were 64 C2 screws placed in group A, and 95.31% achieved a grade A accuracy rating, including 52 screws in group A1 (96.15% grade A) and 12 screws in group A2 (91.67% grade A). A total of 64 C2 screws were placed in group B, and 84.38% achieved a grade A accuracy rating, including 50 screws in group B1 (84.00% grade A) and 14 screws in group B2 (85.71% grade A). The accuracy of screw placement differed significantly between groups A and B (P=0.041) and between groups A1 and B1 (P=0.039) but not between groups A2 and B2 (P=0.636). The postoperative efficacy of the 2 groups was satisfactory. And there were no complications of blood vessels or nerves related to screw placement in either group.
CONCLUSIONS: Although 3D-printed navigation template-assisted and C-arm based navigation-assisted C2 pedicle and pars screw placement provided similar safety and clinical efficacy, 3D-printed navigation template technology achieved more accurate C2 pedicle screw placement.
Keywords: Imaging, Three-Dimensional, Patient Navigation, Surgical Flaps, Cervical Vertebrae, Pedicle Screws, Perioperative Care, Printing, Three-Dimensional, Spinal Fractures, visual analog scale
Editorial
01 January 2026 : Editorial
Editorial: Increasing Awareness of Lung Cancer in Non-Smokers and Never-Smokers Challenges Current Approaches to Prevention and ScreeningDOI: 10.12659/MSM.952454
Med Sci Monit 2026; 32:e952454
In Press
Clinical Research
Institutional and Regional Variations in Access to Clinical Trials and Next-Generation Sequencing in Turkis...Med Sci Monit In Press; DOI: 10.12659/MSM.951027
Clinical Research
Low-Intensity Blood Flow-Restricted Multi-Joint Exercise Improves Muscle Function in Patients With Patellof...Med Sci Monit In Press; DOI: 10.12659/MSM.950516
Review article
Musculoskeletal Ultrasound and MRI in the Evaluation of Chemotherapy-Induced Peripheral Neuropathy: A ReviewMed Sci Monit In Press; DOI: 10.12659/MSM.951283
Clinical Research
Sensory Processing, Dissociation, and Affective Symptoms in Misophonia: A Cross-Sectional Study of 35 AdultsMed Sci Monit In Press; DOI: 10.12659/MSM.950938
Most Viewed Current Articles
17 Jan 2024 : Review article 10,187,196
Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron VariantDOI :10.12659/MSM.942799
Med Sci Monit 2024; 30:e942799
13 Nov 2021 : Clinical Research 3,708,487
Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...DOI :10.12659/MSM.932788
Med Sci Monit 2021; 27:e932788
14 Dec 2022 : Clinical Research 2,341,643
Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase LevelsDOI :10.12659/MSM.937990
Med Sci Monit 2022; 28:e937990
16 May 2023 : Clinical Research 706,524
Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...DOI :10.12659/MSM.940387
Med Sci Monit 2023; 29:e940387