Logo Medical Science Monitor

Call: +1.631.470.9640
Closed: National Holiday

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

26 January 2020 : Clinical Research  

Needle-Guided Suture Technique for Lumbar Annular Fiber Closure in Microendoscopic Discectomy: A Technical Note and Case Series

Kefeng Luo1ABDE, Kaiwen Cai1BCDEF, Guoqiang Jiang1ACDF*, Bin Lu1ACF, Bing Yue1BC, Jiye Lu1CD, Kai Zhang1BF

DOI: 10.12659/MSM.918619

Med Sci Monit 2020; 26:e918619

Abstract

BACKGROUND: Annular fiber closure techniques have been proven effective in reducing short-term recurrence after discectomy. However, annular fiber closure devices are expensive and still fail at a low rate. We present a novel suture method, needle-guided annular closure suture (NGACS) that does not require a special device and can be performed for annular fiber closure following microendoscopic discectomy.

MATERIAL AND METHODS: Twenty-five patients who underwent treatment with NGACS were reviewed by analysis of the medical records. The clinical outcomes were assessed and compared preoperatively and immediately, 1, 6, and 12 months postoperatively. The parameters included the Visual Analog Scale (VAS)-back and VAS-leg scores and the Oswestry Disability Index (ODI). Midsagittal T2WI images were obtained to evaluate lumbar disc degeneration using the Pfirrmann grade. Additional adverse events were also recorded and tracked.

RESULTS: The VAS-back and VAS-leg scores and the ODI were significantly different at each follow-up time point (P<0.001), and improvements in pain and disability were maintained well during the follow-up period. Lumbar disc reherniation or other serious adverse events were not observed in this series. There was no significant difference between the initial and final Pfirrmann grades (Z=–1.414, P=0.157). The preoperative average disc height was 9.94±1.97 mm, and the disc height at 12 months after surgery was 9.14±1.88 mm. The average decrease in disc height was 8.11±3.36%.

CONCLUSIONS: This study demonstrates the feasibility and superior clinical outcomes of the NGACS technique. This method can be a good substitution when annular fiber closure devices are not available. Moreover, this technique can be easily popularized due to its low cost and few restrictions.

Keywords: Diskectomy, Endoscopes, Suture Techniques, Wound Closure Techniques, Disability Evaluation, Lumbar Vertebrae, Needles, visual analog scale

Add Comment 0 Comments

Editorial

01 July 2026 : Editorial  

Editorial: The WHO Identifies Ebola Disease Due to Bundibugyo Virus as a Public Health Emergency of International Concern (PHEIC) as Vaccine Development Accelerates

Dinah V. Parums ORCID logo

DOI: 10.12659/MSM.954627

Med Sci Monit 2026; 32:e954627

0:00

In Press

Clinical Research  

Body Weight and Insulin Resistance Indicators Among Children

Med Sci Monit In Press; DOI: 10.12659/MSM.951434  

Clinical Research  

Comparison of Radiographic Cervical Sagittal Alignment Parameters in Patients With Nonspecific Neck Pain, D...

Med Sci Monit In Press; DOI: 10.12659/MSM.952950  

Clinical Research  

Combined Fibrinogen and Urinary α1-Microglobulin as Predictors of Respiratory Tract Infection in Children w...

Med Sci Monit In Press; DOI: 10.12659/MSM.951066  

Database Analysis  

Evaluation of Salivary Total Oxidant Status (TOS) and Total Antioxidant Status (TAS) in Orthodontic Patient...

Med Sci Monit In Press; DOI: 10.12659/MSM.952052  

Most Viewed Current Articles

17 Jan 2024 : Review article   14,175,576

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,756,620

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,465,966

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   708,651

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750