Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

27 December 2019 : Laboratory Research  

Comparison of Real-Time Two-Dimensional and Three-Dimensional Contrast-Enhanced Ultrasound to Quantify Flow in an In Vitro Model: A Feasibility Study

Si-Min Ruan1EF, Qiao Zheng2EF, Zhu Wang1B, Hang-Tong Hu1C, Li-Da Chen1B, Huan-Ling Guo1B, Xiao-Yan Xie1E, Ming-De Lu13E, Wei Li1AG*, Wei Wang1AEG

DOI: 10.12659/MSM.919160

Med Sci Monit 2019; 25:10029-10035

Abstract

BACKGROUND: This feasibility study aimed to compare real-time two-dimensional contrast-enhanced ultrasound (2D-CEUS) and three-dimensional contrast-enhanced ultrasound (3D-CEUS) to quantify flow in an in vitro model.

MATERIAL AND METHODS: Five polyvinyl chloride (PVC) tubes were used for the perfusion models and used SonoVue ultrasound contrast agent with a perfusion volume ratio of 1: 2: 4: 8: 16. The contrast was injected at a constant speed to compare the raw quantitative data of 2D-CEUS and 3D-CEUS at angles of 0°, 45°, and 90°. The coefficient of variation (CV) of the peak intensity (PI) in the model were compared and the correlations between weighted PI and perfusion volume were analyzed.

RESULTS: In the three angles used, real-time 3D-CEUS resulted in a more comprehensive view of the spatial relationships in the perfusion model. Using real-time 2D-CEUS, the mean CV was 0.92±0.36, and the mean CV in the real-time 3D-CEUS model was significantly less at 0.48±0.32 (p<0.001). Quantitative 3D-CEUS parameters showed a good correlation with those of 2D-CEUS with an r-value of 0.93 (p=0.02). The r-value of weighted PI and the perfusion ratio using 2D-CEUS was 0.66 (p=0.23) compared with values in 3D-CEUS of 0.84 (p=0.08).

CONCLUSIONS: The combination of real-time 3D-CEUS and quantitative analysis identified the spatial distribution of the changes in angle in the model, which was less influenced by sectional planes, and was more representative of the perfusion volume when compared with 2D-CEUS. Quantitative real-time 3D-CEUS requires in vivo studies to evaluate the potential role in the clinical evaluation of vascular perfusion of malignant tumors.

Keywords: Contrast Media, Imaging, Three-Dimensional, in vitro, Ultrasonography, Feasibility Studies, Flow Injection Analysis, Image Enhancement, Image Interpretation, Computer-Assisted, Models, Anatomic, Models, Structural, Perfusion, perfusion imaging, Phospholipids, Sulfur Hexafluoride

Add Comment 0 Comments

Editorial

01 January 2026 : Editorial  

Editorial: Increasing Awareness of Lung Cancer in Non-Smokers and Never-Smokers Challenges Current Approaches to Prevention and Screening

Dinah V. Parums ORCID logo

DOI: 10.12659/MSM.952454

Med Sci Monit 2026; 32:e952454

0:00

In Press

Clinical Research  

Institutional and Regional Variations in Access to Clinical Trials and Next-Generation Sequencing in Turkis...

Med Sci Monit In Press; DOI: 10.12659/MSM.951027  

Clinical Research  

Low-Intensity Blood Flow-Restricted Multi-Joint Exercise Improves Muscle Function in Patients With Patellof...

Med Sci Monit In Press; DOI: 10.12659/MSM.950516  

Review article  

Musculoskeletal Ultrasound and MRI in the Evaluation of Chemotherapy-Induced Peripheral Neuropathy: A Review

Med Sci Monit In Press; DOI: 10.12659/MSM.951283  

Clinical Research  

Sensory Processing, Dissociation, and Affective Symptoms in Misophonia: A Cross-Sectional Study of 35 Adults

Med Sci Monit In Press; DOI: 10.12659/MSM.950938  

Most Viewed Current Articles

17 Jan 2024 : Review article   10,187,196

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,708,487

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,341,643

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   706,524

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750