29 October 2018 : Animal Research  

Comparison of Noninvasive Dynamic Indices of Fluid Responsiveness Among Different Ventilation Modes in Dogs Recovering from Experimental Cardiac Surgery

Kazumasu Sasaki12ABDEFG*, Tatsushi Mutoh2ADEF, Shuzo Yamamoto2CEF, Yasuyuki Taki2E, Ryuta Kawashima2E

DOI: 10.12659/MSM.910135

Med Sci Monit 2018; 24: ANS7736-7741

Abstract

BACKGROUND: Fluid resuscitation is a cornerstone of minimizing morbidity and mortality in critically ill patients, but the techniques for predicting fluid responsiveness is still a matter of debate. In this study, we aimed to evaluate the utility of noninvasive stroke volume variation (SVV), pulse pressure variation (PPV), and systolic pressure variation (SPV) as a dynamic predictor for assessing fluid responsiveness during different ventilation modes in anaesthetized, intubated dogs recovering from cardiac surgery.

MATERIAL AND METHODS: Thirty-six adult Beagle dogs undergoing experimental surgery for isolated right ventricular failure were monitored for SVV, PPV, and SPV simultaneously using electrical velocimetry device. The relationships between each indicator and SVI before and after volume loading were compared in 3 ventilatory modes: assist control (A/C), synchronized intermittent mandatory ventilation (SIMV), and continuous positive airway pressure (CPAP). Responders were defined as those whose stroke volume index increased by ≥10%.

RESULTS: In all of the indices, the baseline values were greater in responders than in nonresponders (P<0.01) under A/C and SIMV. Receiver operating curve analysis confirmed the best predictive value during A/C [area under the curve (AUC): SVV, 0.90; PPV, 0.88; SPV, 0.85; P<0.05] followed by SIMV (AUC: SVV, 0.86; PPV, 0.83; CPAP, 0.80; P<0.05), with their sensitivities and specificities of ≥7 5%. By contrast, no statistically significance detected in any parameter during CPAP (AUC: SVV, 0.71; PPV, 0.66; CPAP, 0.65; P>0.05).

CONCLUSIONS: SVV, PPV, and SVV are all useful to predict cardiac response to fluid loading in dogs during A/C and SIMV, while their reliabilities during CPAP are poor.

Keywords: Blood Pressure, Dogs, Monitoring, Intraoperative, Respiration, Artificial, Stroke Volume, Fluid Therapy

Add Comment 0 Comments

Editorial

01 July 2026 : Editorial  

Editorial: The WHO Identifies Ebola Disease Due to Bundibugyo Virus as a Public Health Emergency of International Concern (PHEIC) as Vaccine Development Accelerates

Dinah V. Parums ORCID logo

DOI: 10.12659/MSM.954627

Med Sci Monit 2026; 32:e954627

0:00

In Press

Clinical Research  

Effect of Dexmedetomidine Hydrochloride Nasal Spray on Anxiety and Sleep in Patients Undergoing Gynecologic...

Med Sci Monit In Press; DOI: 10.12659/MSM.952465  

Clinical Research  

Prognostic Value of Mortality Scoring Systems in Patients With Severe Burns: Identifying Key Predictors of ...

Med Sci Monit In Press; DOI: 10.12659/MSM.951713  

Laboratory Research  

Evaluation of the Trueness and Precision of Cast, Milled-Cast, Milled, and 3D-Printed Post-and-Core Techniq...

Med Sci Monit In Press; DOI: 10.12659/MSM.953491  

Clinical Research  

Outcomes After Minimally Invasive Intramedullary Nail Fixation and Locking Plate Fixation Among Patients Wi...

Med Sci Monit In Press; DOI: 10.12659/MSM.952670  

Most Viewed Current Articles

17 Jan 2024 : Review article   14,176,214

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,757,839

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,466,153

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   708,809

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750