Evaluation of Temperature and Stress Distribution on 2 Different Post Systems Using 3-Dimensional Finite Element Analysis

Yalçın Değer AEF , Özkan Adigüzel BD , Senem Yiğit Özer EF , Sadullah Kaya CDG , Zelal Seyfioğlu Polat CD , Bejna Bozyel DF

DOI: 10.12659/MSM.896132

Med Sci Monit 2015; 21:3716-3721

0 Comments

Abstract

BACKGROUND: The mouth is exposed to thermal irritation from hot and cold food and drinks. Thermal changes in the oral cavity produce expansions and contractions in tooth structures and restorative materials. The aim of this study was to investigate the effect of temperature and stress distribution on 2 different post systems using the 3-dimensional (3D) finite element method.

MATERIAL AND METHODS: The 3D finite element model shows a labio-lingual cross-sectional view of the endodontically treated upper right central incisor and supporting periodontal ligament with bone structures. Stainless steel and glass fiber post systems with different physical and thermal properties were modelled in the tooth restored with composite core and ceramic crown. We placed 100 N static vertical occlusal loading onto the center of the incisal surface of the tooth. Thermal loads of 0°C and 65°C were applied on the model for 5 s. Temperature and thermal stresses were determined on the labio-lingual section of the model at 6 different points.

RESULTS: The distribution of stress, including thermal stress values, was calculated using 3D finite element analysis. The stainless steel post system produced more temperature and thermal stresses on the restorative materials, tooth structures, and posts than did the glass fiber reinforced composite posts.

CONCLUSIONS: Thermal changes generated stresses in the restorative materials, tooth, and supporting structures.

Keywords: Cross-Sectional Studies, Body Temperature, Dental Implants, Dental Materials - chemistry, Dental Porcelain - chemistry, Dental Prosthesis Design - methods, Finite Element Analysis, Humans, Incisor - chemistry, Models, Anatomic, Stress, Mechanical

Background

Endodontically-treated teeth are usually weakened and become more susceptible to fractures due to the loss of dental hard tissue structure by caries, cavity preparation, root canal shaping and instrumentation, and decrease in dentin moisture [1]. A widely used method for the treatment of structurally weakened teeth is the post-and-core system [1,2]. Prefabricated posts may be non-metallic (e.g., carbon fiber, zirconium, and resin composites reinforced with glass fiber) or metal (e.g., stainless steel and titanium). Metallic posts are luted to the root canal with zinc phosphate cement, and non-metallic posts are luted with adhesive bondings [3,4].

With advances in materials and technology, several new non-metal post materials, such as carbon fiber and glass fiber post systems have recently become available [5–8]. Although use of cast metal posts has been most common, the glass fiber reinforced post-core system is gaining in popularity in recent years [9].

Glass fiber post systems show much better esthetic results than metal posts. While metallic posts are prone to fatigue failure and corrosion, glass fiber post systems meet the requirements of mechanical strength and retention. Their elastic modulus, being similar to dentin, reduces stress on the post-dentin interface [10].

The oral environment is exposed to thermal stimuli with consumption of hot and cold food and drinks [11]. Palmer et al. identified maximum and minimum temperatures between 0°C and 67°C in hot and cold liquid using a digital thermometer probe [12]. They concluded that thermal conductivity and expansion values of metal, dentin, and non-metallic restorative materials are different [12].

Stress distribution analysis of prefabricated post applications have been studied by many researchers using different theoretical or experimental techniques [7,9,10]. With rapid improvements in computer technology, the finite element method (FEM) was shown to be a powerful method and numerical model for evaluating behavior of a post-dentin interface [13]. FEM was originally developed in the aircraft industry for stress analysis in 1956; this technique is used in engineering fields, as well as in dentistry, due to its flexibility [14]. FEM plays an important role in determining clinical and biomechanical states of thermal conditions in different areas of dentistry. Computer programs allow calculation of stress, strain, and deformations [15,16].

The aim of this study was to compare and evaluate the stress distributions on an endodontically treated tooth with stainless steel and glass fiber posts under thermal and mechanical loads.

Material and Methods

An endodontically treated maxillary central incisor was modeled to include the periodontal ligament and alveolar bone (Figure 1). Thermal properties of materials, elastic modulus values, and Poisson’s ratios are given in Table 1 in accordance with the literature. Temperature and thermal stresses were determined on the labio-lingual section of the model at 6 different points (Figure 2).

The model placed static vertical occlusal force of 100 N onto the middle of the occlusal surface of the tooth. Rhinoceros 4.0 software (Seattle, USA) was used for modeling and Algor Fempro software (ALGOR, Inc. Pittsburgh, USA) was used for stress analysis. Stress distribution and values were calculated taking into consideration 3D Von Mises criteria. The thermal loads were applied to have an initial value of 0°C (Figure 3, 4), and 65°C for the hot liquids (Figures 5, 6). Thermal stress levels were measured after 5 s. These temperature ranges and times were selected based on previous studies [11,12].

Results

Stress was observed in the middle third of the root. In contrast, minimum values were observed both in the apical portion of the post and in the root apex. Assessments were made according to the color changes in Figures 3–6, in which warm colors denote higher stresses.

Temperature and thermal stresses of the model on 6 different points are shown in Table 2. Numerical calculations were made according to the Von Mises criteria. For better observation, stress values were converted to the color chart. All stress levels were measured in megapascals.

Analyses of Von Mises values for the stainless steel post showed that the maximum stress concentration was on the highest peak surface of the post and coronal third, between 550.364 and 653.678 Mpa. For the glass fiber post model, it showed that the maximum stress concentration was on the highest peak surface of the post and coronal third, between 389.957 and 521.704 Mpa. Analyses of thermal stress values for the stainless steel post showed that the maximum stress concentration was on the highest peak surface of the post and coronal third, between 12.504 and 46.137 Mpa. Analyses of thermal stress values for the glass fiber post showed that the maximum stress concentration was on the highest peak surface of the post and coronal third, between 6.035 and 6.427 Mpa.

Discussion

Many studies have evaluated variables related to the use of posts using mechanical tests. Destructive tests, such as fracture mechanics testing, are important in the biomechanical analysis of teeth and restorative materials, but they have very limited ability to calculate complex stress and strain between the tooth and restoration surfaces [25–28]. Non-destructive testings, such as strain gauge [29] and FEM test [30–32], are more appropriate tools for calculation of the distribution of stress in this area [33–37].

In investigations of complex biomechanical structures, finite element analysis (FEA) works by dividing a problem domain into small elements and executing an element-level computation to generate a piecewise solution, which cannot be revealed by direct experimental techniques. Rapid progress and development in computer technology have increased the accuracy of FEM analysis. Finite element analysis has become a powerful method in measuring internal stress when investigating complex systems that are difficult to standardize during in vitro and in vivo studies [38,39].

Correctly done, FEM analysis can describe how the stress distribution between dental tissue and dental materials occurs. The dental restoration of endodontically treated teeth has an important place in dentistry practice. Lately, post and core restorations have become viable options for endodontically treated teeth and this treatment can make teeth more brittle and susceptible to fracture [40].

High compressive or tensile stress concentrated around posts may lead to root fractures and may result a new cracks or worsen an existing crack along with tooth surface [41,42].

Our study, which compared stainless steel and glass fiber posts under thermal and mechanical loads, determined the effectiveness of post different material types.

The modulus of elasticity of metal is much higher than that of dentine. This results in a system that can lead to a catastrophic, unrestorable fracture [43]. The high elasticity modulus and high fracture resistance of cast metallic dowels make the teeth highly susceptible to catastrophic fractures under intense occlusal forces [21]. Young’s modulus of glass fiber posts is close to that of dentine and exhibits higher fatigue and tensile strength [22]. Teeth restored with fiber posts showed higher resistance than metallic posts under static loading.

Hot and cold liquids cause thermal stress over time. This phenomenon is a serious condition that should be investigated. Drinking hot liquids causes more thermal stress on stainless steel posts, and glass fiber posts exhibit less thermal stress behavior. Stainless steel post has more thermal stress than glass fiber post systems.

According to the results of the present study, post material, post design, and post mechanical properties are very important in stress distribution. The numerical results indicated that the mechanical behavior in the root dentin was affected by post material and temperature.

Conclusions

We conclude that thermal and physical properties of the posts affected stress distribution in post and core applications. Our study showed that when thermal heat is applied, stainless steel posts create more stress than glass fiber posts.

References

1. Santos-Filho PC, Veríssimo C, Raposo LH, Influence of ferrule, post system, and length on stress distribution of weakened root-filled teeth: J Endod, 2014; 40; 1874-78, pmid: 25227215

2. Joshi S, Mukherjee A, Kheur M, Mehta A, Mechanical performance of endodontically treated teeth: Finite Elements in Analysis and Design, 2001; 37; 587-601

3. Sahafi A, Peutzfeldt A, Ravnholt G, Resistance to cyclic loading of teeth restored with posts: Clin Oral Invest, 2005; 9; 84-90

4. Sumer E, Deger Y, Contemporary permanent luting agents used in dentistry: A literature review: Int Dent Res, 2011; 1; 26-31

5. Lassila LVJ, Tanner J, Le-Bell AM, Flexural properties of fiber reinforced root canal posts: Dent Mat, 2004; 20; 29-36

6. Aguloglu S, Ayna E, Ozdemir E, A Fibre-Reinforced fixed partial denture on a hemisectioned tooth: A Case Report: Int Dent Res, 2011; 1; 38-41

7. Kainose K, Nakajima M, Foxton R, Stress distribution in root filled teeth restored with various post and core techniques: effect of post length and crown height: Int Endod J, 2015; 48; 1023-32, pmid: 25314030

8. Ramírez-Sebastià A, Bortolotto T, Cattani-Lorente M, Adhesive restoration of anterior endodontically treated teeth: influence of post length on fracture strength: Clin Oral Investig, 2014; 18(2); 545-54

9. Qualtrough AJ, Mannocci F, Tooth-colored post system: a review: Oper Dent, 2003; 28; 86-91, pmid: 12540124

10. Santos AF, Meira JB, Tanaka CB, Can fiber posts increase root stresses and reduce fracture?: J Dent Res, 2010; 89; 587-91, pmid: 20348486

11. Yang HS, Lang LA, Guckes AD, Felton DA, The effect of thermal change on various dowel-and-core restorative materials: J Prosthet Dent, 2001; 86; 74-80, pmid: 11458265

12. Palmer DS, Barco MT, Billy EJ, Temperature extremes produced orally by hot and cold liquids: J Prosthet Dent, 1992; 67; 325-27, pmid: 1507094

13. Asmussen E, Peutzfeldt A, Sahafi A, Finite element analysis of stresses in endodontically treated, dowel-restored teeth: J Prosthet Dent, 2005; 94; 321-29, pmid: 16198168

14. Thresher RW, Saito GE, The stress analysis of human teeth: J Biomech, 1973; 6; 443-49, pmid: 4748494

15. Eskitascioglu G, Usumez A, Sevimay M, The influence of occlusal loading location on stresses transferred to implant-supported prostheses and supporting bone: a three-dimensional finite element study: J Prosthet Dent, 2004; 91; 144-50, pmid: 14970760

16. Eraslan Ö, Eraslan O, Eskitaşcıoğlu G, Belli S, Conservative restoration of severely damaged endodontically treated premolar teeth: a FEM study: Clin Oral Invest, 2011; 15; 403-8

17. Ko CC, Chu CS, Chung KH, Lee MC, Effects of posts on dentin stress distributions in pulpless teeth: J Prosthet Dent, 1992; 68; 421-27, pmid: 1432755

18. Asmussen E, Peutzfeldt A, Heitmann T, Stifness, elastic limit and strength of newer types of endodontic posts: J Dent, 1999; 27(4); 275-78, pmid: 10193104

19. Toparlı M, Aykul H, Sasaki S, Evaluation of the onset of failure under mechanical and thermal stresses on luting agent for metal-ceramic and metal crowns by finite element analysis: J Oral Reh, 2003; 30; 99-105

20. Holmes DC, Diaz-Arnold AM, Leary JM, Influence of post dimension on stress distribution in dentin: J Prosthet Dent, 1996; 75; 140-47, pmid: 8667271

21. Lanza A, Aversa R, Rengo S, 3D FEA of cemented steel, glass and carbon posts in a maxillary incisor: Dent Mater, 2005; 21; 709-15, pmid: 16026666

22. Hsu ML, Chen CS, Chen BJ, Effects of post materials and length on the stress distribution of endodontically treated maxillary central incisors: a 3D finite element analysis: J Oral Reh, 2009; 36; 821-30

23. Geng JP, Tan Keson BC, MSD , Liu GR, Application of finite element analysis in implant dentistry: A review of the literatüre: J Prosthet Dent, 2001; 85; 585-98, pmid: 11404759

24. Kacan U: Oral sıcaklık degisikliklerinin farklı yapıdaki restoratif post ve kor materyaller üzerindeki termal stres etkisinin üç boyutlu sonlu elemanlar termal analiz yöntemi ile karşılaştırılması, 2006, Hacettepe Universitesi, Sağlık Bilimleri Enstitüsü, Protetik Diş Tedavisi Anabilim Dalı [in Turkish]

25. Soares CJ, Santana FR, Silva NR, Influence of the endodontic treatment on mechanical properties of root dentin: J Endodon, 2007; 33; 603-6

26. Soares CJ, Fonseca RB, Gomide HA, Correr-Sobrinho L: Braz Oral Res, 2008; 22; 281-87, pmid: 18949317

27. Fokkinga WA, Kreulen CM, Le Bell-Ronnlof AM: Eur J Oral Sci, 2006; 114; 250-56, pmid: 16776775

28. Isidor F, Brondum K, Ravnholt G, The influence of post length and crown ferrule length on the resistance to cyclic loading of bovine teeth with prefabricated titanium posts: Int J Prosthodont, 1999; 12; 78-82, pmid: 10196832

29. Ross RS, Nicholls JI, Harrington GW, A comparison of strains generated during placement of five endodontic posts: J Endodon, 1991; 17; 450-56

30. Kishen A, Kumar GV, Chen NN, Stress-strain response in human dentine: rethinking fracture predilection in postcore restored teeth: Dent Traumatology, 2004; 20; 90-100

31. Jacobsen PH, Wakefieldt AJ, O’Doherty DM, Rees JS, The effect of preparation height and taper on cement lute stress: a three-dimensional finite element analysis: Eur J Prosthodont Restor Dent, 2006; 14; 151-57, pmid: 17205949

32. Adıgüzel Ö, Kaya S, Yiğit Özer S, Three-dimensional finite element analysis of endodontically treated tooth restored with carbon and titanium posts: Int Dent Res, 2011; 1(2); 55-59

33. Lin CL, Chang CH, Ko CC, Multifactorial analysis of an MOD restored human premolar using auto-mesh finite element approach: J Oral Reh, 2001; 28; 576-85

34. Magne P, Belser UC, Porcelain versus composite inlays/onlays: effects of mechanical loads on stress distribution, adhesion, and crown flexure: Int J Periodontics Restorative Dent, 2003; 23; 543-55, pmid: 14703758

35. Adiguzel O, Cone beam computed tomography in endodontic applications: A review: Int Dent Res, 2015; 1(1); 1-10

36. Fennis WM, Kuijs RH, Barink M, Can internal stresses explain the fracture resistance of cusp-replacing composite restorations?: Euro J Oral Sci, 2005; 113; 443-48

37. Adıgüzel Ö, Yiğit Özer S, Bahşi E, Yavuz İ, Finite element analysis of endodontically treated tooth restored with different posts under thermal and mechanical loading: Int Dent Res, 2011; 1(3); 75-80

38. Chuang SF, Yaman P, Herrero A: J Prosthet Dent, 2010; 104; 379-88, pmid: 21095401

39. Karadede İ, Adıgüzel Ö, Özer T, Virtual modeling of a cleft lip and palate patient: Int Dent Res, 2012; 2(1); 43-47

40. Melo MP, Valle AL, Pereira JR, Evaluation of fracture resistance of endodontically treated teeth restored with prefabricated posts and composites with varying quantities of remaining coronal tooth structure: J Appl Oral Sci, 2005; 13(2); 141-46, pmid: 20924538

41. Adiguzel O, Finite element analysis in Dentistry: Int Dent Res, 2013; 1(1); 1-10

42. Yamamoto ETC, Pagani C, Silva EG, Finite element analysis and fracture resistance testing of a new intraradicular post: J Appl Oral Sci, 2012; 20(4); 427-34, pmid: 23032204

43. Adiguzel O, Finite element analysis applications in Endodontics: Int Dent Res, 2014; 1(1); 1-6

In Press

Clinical Research  

Institutional and Regional Variations in Access to Clinical Trials and Next-Generation Sequencing in Turkis...

Med Sci Monit In Press; DOI: 10.12659/MSM.951027  

Clinical Research  

Low-Intensity Blood Flow-Restricted Multi-Joint Exercise Improves Muscle Function in Patients With Patellof...

Med Sci Monit In Press; DOI: 10.12659/MSM.950516  

Review article  

Musculoskeletal Ultrasound and MRI in the Evaluation of Chemotherapy-Induced Peripheral Neuropathy: A Review

Med Sci Monit In Press; DOI: 10.12659/MSM.951283  

Clinical Research  

Sensory Processing, Dissociation, and Affective Symptoms in Misophonia: A Cross-Sectional Study of 35 Adults

Med Sci Monit In Press; DOI: 10.12659/MSM.950938  

Most Viewed Current Articles

17 Jan 2024 : Review article   10,187,196

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,708,487

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,341,643

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   706,524

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750