Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

29 March 2016 : Clinical Research  

Single-Level Rigid Fixation Combined with Coflex: A Biomechanical Study

Wu CheABCDE, Qian ChenABCDE, Yi-Qun MaCD, Yun-Qi JiangE, Wei YuanE, Xiao-Gang ZhouF, Xi-Lei LiD, Jian DongAEG

DOI: 10.12659/MSM.896706

Med Sci Monit 2016; 22:1022-1027

Abstract

BACKGROUND: The purpose of this biomechanical in vitro study was to compare the kinematics and intradiscal pressure achieved with 2 methods: L4–L5 pedicle screw-rod fixation (PSRF) with an upper L3–L4 Coflex device and L4–L5 PSRF alone. The results were used to characterize the biomechanics of the topping-off operation with a Coflex device for the lumbar motion segment adjacent to single-level rigid fixation.

MATERIAL AND METHODS: Six human cadaveric spine specimens were biomechanically tested in vitro (6 males, 0 females). The 3-dimensional specimen motion in response to applied loads during flexibility tests was determined. Loads were applied along anatomic axes to induce flexion-extension, lateral bending, and axial rotation. All specimens were first studied with intact lumbar motion segments, then with L4–L5 PSRF alone, and finally with L4–L5 PSRF with an upper L3–L4 Coflex device. A non-paired comparison of the 3 configurations under 3 different conditions was made.

RESULTS: PSRF, with or without a Coflex device, significantly increased the range of motion (ROM) in the upper adjacent motion segments in all directions of loading. The intradiscal pressure (IDP) changed slightly. A correlation analysis showed that the ROM and IDP are significantly positively correlated. The application of the upper motion segment of the Coflex device provided greater stability in all directions of motion than did PSRF alone, particularly for extension (p<0.05), while use of a Coflex device did not significantly decrease the IDP compared with PSRF alone (p>0.05).

CONCLUSIONS: These results suggest that L4–L5 PSRF with an L3–L4 Coflex device is more stable than L4–L5 PSRF alone. PSRF with an upper Coflex device is a promising alternative to PSRF alone. Based on these biomechanical tests, it might be considered a protective method to prevent adjacent segment degeneration (ASD), although some limitations with this in vitro study must be addressed in the future.

Keywords: Biomechanical Phenomena, Intervertebral Disc - physiology, Lumbar Vertebrae - physiology, Orthopedic Fixation Devices, Range of Motion, Articular, Torque

Add Comment 0 Comments

Editorial

01 March 2025 : Editorial  

Editorial: The World Health Organization (WHO) Updated List of Emerging and Potentially Pandemic Pathogens Includes Yersinia pestis as Plague Vaccines Await Clinical Trials

Dinah V. Parums

DOI: 10.12659/MSM.948672

Med Sci Monit 2025; 31:e948672

0:00

In Press

Clinical Research  

Impact of Cholecalciferol Supplementation on Radiotherapy Outcomes in Advanced Cervical Cancer

Med Sci Monit In Press; DOI: 10.12659/MSM.945964  

Clinical Research  

Inflammatory Biomarkers in Smokers: Implications for Ligamentum Flavum Hypertrophy

Med Sci Monit In Press; DOI: 10.12659/MSM.947508  

Clinical Research  

Balancing Image Quality and Iodine Intake: Insights from CT Spectral Imaging of the Portal Vein

Med Sci Monit In Press; DOI: 10.12659/MSM.947391  

Review article  

Regulatory Efforts and Health Implications of Energy Drink Consumption by Minors in Poland

Med Sci Monit In Press; DOI: 10.12659/MSM.947124  

Most Viewed Current Articles

17 Jan 2024 : Review article   7,160,485

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

16 May 2023 : Clinical Research   702,385

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

01 Mar 2024 : Editorial   27,806

Editorial: First Regulatory Approvals for CRISPR-Cas9 Therapeutic Gene Editing for Sickle Cell Disease and ...

DOI :10.12659/MSM.944204

Med Sci Monit 2024; 30:e944204

0:00

28 Jan 2024 : Review article   22,071

A Review of IgA Vasculitis (Henoch-Schönlein Purpura) Past, Present, and Future

DOI :10.12659/MSM.943912

Med Sci Monit 2024; 30:e943912

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750