21 January 2017 : Clinical Research
Leukocyte Esterase as a Biomarker in the Diagnosis of Periprosthetic Joint Infection
Chi Wang1CDE, Rui Li2BD, Qi Wang2EF, Jinyan Duan1C, Chengbin Wang1AFG*DOI: 10.12659/MSM.899368
Med Sci Monit 2017; 23:353-358
Abstract
BACKGROUND: Total joint arthroplasty (TJA) has been one of the most rewarding interventions for treating patients suffering from joint disorders. However, periprosthetic joint infection (PJI) is a serious complication that frequently accompanies TJA. Our study aimed to investigate the application of the leukocyte esterase (LE) strip in the diagnosis of PJI.
MATERIAL AND METHODS: From October 2014 to July 2015, 72 patients who had undergone joint puncture after arthroplasty in our hospital were enrolled in this trial. One drop of synovial fluid from each available patient was applied to the LE strip, and the results were observed after 1–3 min. If the color turned to dark purple, we recognized this as a positive result, while other colors were regarded as negative results. Centrifugation was used when the synovial fluid was mixed with blood. The Musculoskeletal Infection Society (MSIS) definition was used as the standard reference to identify whether PJI was found in patients or not. The results of diagnosis and LE strips test were compared, and indicators reflecting diagnostic value were calculated. Correlation of the LE data with erythrocyte sedimentation rate (ESR), elevated C-reactive protein (CRP), synovial white blood cell (WBC) counts, and polymorphonuclear neutrophil (PMN) percentage was calculated.
RESULTS: By MSIS criteria, 38 patients were diagnosed with PJI and 34 patients were not infected. Two types of LE strip presented the same results with sensitivity of 84.21% (95% confidence interval [CI]: 68.75~93.98%), specificity of 97.06% (95% CI: 84.67~99.93%), positive predictive value (PPV) of 96.97% (95% CI: 84.24~99.92%), and negative predictive value (NPV) of 84.62% (95% CI: 69.47~94.14%). There were one false-positive case and six false-negative cases in this trial. There is a strong correlation between LE strip and synovial fluid PMN percentage.
CONCLUSIONS: The sensitivity and specificity of the LE strip in the diagnosis of PJI are quite high, which means the LE strip might be used as an alternative to diagnose PJI in clinical practice.
Keywords: Arthritis, Infectious, Arthroplasty, Replacement, Esterases, Leukocytes
Editorial
01 January 2026 : Editorial
Editorial: Increasing Awareness of Lung Cancer in Non-Smokers and Never-Smokers Challenges Current Approaches to Prevention and ScreeningDOI: 10.12659/MSM.952454
Med Sci Monit 2026; 32:e952454
In Press
Clinical Research
Institutional and Regional Variations in Access to Clinical Trials and Next-Generation Sequencing in Turkis...Med Sci Monit In Press; DOI: 10.12659/MSM.951027
Clinical Research
Low-Intensity Blood Flow-Restricted Multi-Joint Exercise Improves Muscle Function in Patients With Patellof...Med Sci Monit In Press; DOI: 10.12659/MSM.950516
Review article
Musculoskeletal Ultrasound and MRI in the Evaluation of Chemotherapy-Induced Peripheral Neuropathy: A ReviewMed Sci Monit In Press; DOI: 10.12659/MSM.951283
Clinical Research
Sensory Processing, Dissociation, and Affective Symptoms in Misophonia: A Cross-Sectional Study of 35 AdultsMed Sci Monit In Press; DOI: 10.12659/MSM.950938
Most Viewed Current Articles
17 Jan 2024 : Review article 10,187,196
Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron VariantDOI :10.12659/MSM.942799
Med Sci Monit 2024; 30:e942799
13 Nov 2021 : Clinical Research 3,708,487
Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...DOI :10.12659/MSM.932788
Med Sci Monit 2021; 27:e932788
14 Dec 2022 : Clinical Research 2,341,643
Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase LevelsDOI :10.12659/MSM.937990
Med Sci Monit 2022; 28:e937990
16 May 2023 : Clinical Research 706,524
Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...DOI :10.12659/MSM.940387
Med Sci Monit 2023; 29:e940387






