13 May 2017 : Clinical Research
Comparison of Echocardiography and 64-Multislice Spiral Computed Tomography for the Diagnosis of Pediatric Congenital Heart Disease
Aiyin Li1ABE, Zhenpeng Peng2CD, Chengqi Zhang1BF*DOI: 10.12659/MSM.901546
Med Sci Monit 2017; 23:2258-2266
Abstract
BACKGROUND: The goals of this study were: to compare echocardiogram and 64-multislice spiral computed tomography (64-MSCT) in diagnosing pediatric congenital heart disease; to determine the significance of ECHO for diagnosing congenital heart disease; and to identify the appropriate diagnosis for congenital heart disease through combined use of 64-MSCT and ECHO.
MATERIAL AND METHODS: Thirty patients underwent both ECHO and 64-MSCT diagnoses before their surgeries. Imaging from ECHO and 64-MSCT were analyzed by 4 specialists. The diagnostic accuracy and kappa value of ECHO and 64-MSCT were evaluated based on the operation results. The accuracy of the 2 methods was evaluated using the McNemar χ² test.
RESULTS: We confirmed 138 malformations in 30 children by surgery. The diagnostic accuracy of ECHO and 64-MSCT was 98.40% and 96.20%, respectively, with a significant difference between the 2 results (χ²=6.404, P=0.011). We compared prognosis accuracy and uniformity on 3 types of congenital heart disease (cardiac malformation, heart-large vascular connecting malformation, and large vascular malformation): 56 cardiac malformations were confirmed by surgery, in which the diagnostic accuracy of ECHO and 64-MSCT was 99.50% and 94.80%, respectively. (χ²=8.578, P=0.034); 31 heart-large vascular connecting malformations were confirmed by surgery, in which the diagnostic accuracy of ECHO and 64-MSCT was 99.00% and 95.42% (χ²=6.779, P=0.009); and 51 vascular malformations were confirmed, in which the diagnostic accuracy of ECHO and 64-MSCT was 96.30% and 98.30% (χ²=1.806, P=0.179).
CONCLUSIONS: ECHO is more effective than 64-MSCT in preoperative diagnosis of congenital heart disease, especially for children.
Keywords: Heart Defects, Congenital, Pediatrics, Tomography, Spiral Computed
Editorial
01 October 2024 : Editorial
Editorial: Potentials and Pitfalls in Targeting Glucagon-Like Peptide-1 (GLP-1) in the Management of Increasing Levels of ObesityDOI: 10.12659/MSM.946675
Med Sci Monit 2024; 30:e946675
In Press
Review article
Lamotrigine: A Safe and Effective Mood Stabilizer for Bipolar Disorder in Reproductive-Age AdultsMed Sci Monit In Press; DOI: 10.12659/MSM.945464
Clinical Research
Impact of Manual Sustained Inflation vs Stepwise PEEP on Pulmonary and Cerebral Outcomes in Carotid Endarte...Med Sci Monit In Press; DOI: 10.12659/MSM.944936
Clinical Research
Predicting Vaginal Delivery Success: Role of Intrapartum Transperineal Ultrasound Angle of Descent at a Sin...Med Sci Monit In Press; DOI: 10.12659/MSM.945458
Review article
Comprehensive Analysis of UBE-Related Complications: Prevention and Management Strategies from 4685 PatientsMed Sci Monit In Press; DOI: 10.12659/MSM.944018
Most Viewed Current Articles
17 Jan 2024 : Review article 6,056,667
Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron VariantDOI :10.12659/MSM.942799
Med Sci Monit 2024; 30:e942799
14 Dec 2022 : Clinical Research 1,848,284
Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase LevelsDOI :10.12659/MSM.937990
Med Sci Monit 2022; 28:e937990
16 May 2023 : Clinical Research 693,649
Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...DOI :10.12659/MSM.940387
Med Sci Monit 2023; 29:e940387
07 Jan 2022 : Meta-Analysis 257,949
Efficacy and Safety of Light Therapy as a Home Treatment for Motor and Non-Motor Symptoms of Parkinson Dise...DOI :10.12659/MSM.935074
Med Sci Monit 2022; 28:e935074