11 June 2020 : Clinical Research  

A Novel Metallic Artifact Reduction Technique When Using a Computed Tomography-Guided Percutaneous Metallic Antenna to Ablate Malignant Pulmonary Nodules: A Qualitative and Quantitative Assessment

Guorong Wang1BCF, Zhiwei Wang1ADE*, Zhengyu Jin1AF

DOI: 10.12659/MSM.923541

Med Sci Monit 2020; 26:e923541

Abstract

BACKGROUND: Metallic microwave ablation (MWA) antenna-related artifacts are usually created in conventional CT images, and these artifacts can influence the effect of ablation. The aim of this study was to evaluate a new type of metal artifact reduction (MAR+) technique in CT-guided MWA for lung cancer.

MATERIAL AND METHODS: This retrospective study enrolled 30 lung cancer patients who received CT-guided MWA treatment from December 2017 to April 2018. Images after microwave antenna insertion into the tumor were reconstructed by the filter back projection (group A) and MAR+ reconstruction (group B). The CT values and standard deviations of the regions of interest (ROIs) on the chosen image were recorded, including the most significantly hypodense artifact (ROI₁), hyperdense artifacts (ROI₂), and chest muscles of the same layer (ROI₃). The metal artifact indexes based on ROI₁ and ROI₂ (AI₁, AI₂) and the overall metal artifact index (AI) were calculated. Subjective image quality was graded on a five-point scale (1=worst, 5=excellent).

RESULTS: The AI₁ (74.14±76.32), AI₂ (13.75±19.02) and AI (54.12±54.82) of group B were lower than those of group A [(153.33±89.04), (30.63±26.42), (112.00±63.10), respectively] (P<0.001 for all). Both radiologists reported that the subjective image value of group B was significantly higher than that of group A (P<0.001). The subjective image quality scores evaluated by 2 observers showed excellent consistency (ICC=0.829).

CONCLUSIONS: The MAR+ imaging reconstruction significantly reduced metal artifacts, which helps radiologists to clearly observe the relationship between the ablation antenna and the lesion.

Keywords: Artifacts, Microwaves, Tomography, X-Ray Computed, Ablation Techniques, Algorithms, Image Processing, Computer-Assisted, Multiple Pulmonary Nodules

Add Comment 0 Comments

Editorial

01 January 2026 : Editorial  

Editorial: Increasing Awareness of Lung Cancer in Non-Smokers and Never-Smokers Challenges Current Approaches to Prevention and Screening

Dinah V. Parums ORCID logo

DOI: 10.12659/MSM.952454

Med Sci Monit 2026; 32:e952454

0:00

In Press

Clinical Research  

Institutional and Regional Variations in Access to Clinical Trials and Next-Generation Sequencing in Turkis...

Med Sci Monit In Press; DOI: 10.12659/MSM.951027  

Clinical Research  

Low-Intensity Blood Flow-Restricted Multi-Joint Exercise Improves Muscle Function in Patients With Patellof...

Med Sci Monit In Press; DOI: 10.12659/MSM.950516  

Review article  

Musculoskeletal Ultrasound and MRI in the Evaluation of Chemotherapy-Induced Peripheral Neuropathy: A Review

Med Sci Monit In Press; DOI: 10.12659/MSM.951283  

Clinical Research  

Sensory Processing, Dissociation, and Affective Symptoms in Misophonia: A Cross-Sectional Study of 35 Adults

Med Sci Monit In Press; DOI: 10.12659/MSM.950938  

Most Viewed Current Articles

17 Jan 2024 : Review article   10,187,196

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,708,487

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,341,643

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   706,524

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750