05 January 2024 : Clinical Research  

Evaluation of Reliability of the Luna EMG Rehabilitation Robot to Assess Proprioception in the Upper Limbs in 102 Healthy Young Adults

Justyna Leszczak ORCID logo1ABDEF*, Andżelina Wolan-Nieroda ORCID logo1BCF, Mariusz Drużbicki ORCID logo1DEF, Anna Poświata ORCID logo2AEF, Michał Mikulski ORCID logo2AEF, Anna Roksela ORCID logo3AEF, Agnieszka Guzik ORCID logo4ADEF

DOI: 10.12659/MSM.942439

Med Sci Monit 2024; 30:e942439

Abstract

0:00

BACKGROUND: Proprioception, the body’s ability to perceive its own position and movement, is fundamental for motor control and coordination. Reliable assessment tools are essential, particularly for conditions affecting proprioceptive function. This study aimed to evaluate the external and internal compliance of the Luna EMG ­multifunction robotic device in assessing proprioception.

MATERIAL AND METHODS: The study involved 102 healthy students (31 men and 71 women; mean age 22.2±1.46 years), assessing proprioception using the Luna EMG for the upper limbs. Two investigators conducted measurements, which were repeated after 2 weeks under identical conditions.

RESULTS: Based on the identified values of the interclass correlation coefficient (ICC) (ICC=0.969-0.997), which is a key measure of agreement between 2 assessments, the study shows a high agreement of measurements both between investigators (for right hand: P=0.3484 [Exam 1]; P=1.0000 [Exam 2]; for left hand: P=0.1092 [Exam 1]; P=0.7706 [Exam 2]) and between the examinations (for right hand: 0.1127 [Investigator 1]; 0.2113 [Investigator 2]; for left hand: P=0.0087 [Investigator 1]; P=0.1466 [Investigator 2]). The Bland-Altman analysis showed very small inter-rater deviations, approximately 0.05° in the first examination for the left side and 0.04° for the right side. The highest deviation between the examinations, amounting to 0.08°, was identified for the left side.

CONCLUSIONS: The study shows that the Luna EMG multifunction robotic device enables a reliable evaluation of upper limb proprioception. Measurements performed using this device show high internal and external consistency in the assessment of the proprioceptive senses of the upper limb in 102 healthy young adults.

Keywords: Proprioception, Robotics, Rehabilitation, Reproducibility of Results, Male, Humans, Female, young adult, adult, Upper Extremity, Hand

Add Comment 0 Comments

Editorial

01 January 2026 : Editorial  

Editorial: Increasing Awareness of Lung Cancer in Non-Smokers and Never-Smokers Challenges Current Approaches to Prevention and Screening

Dinah V. Parums ORCID logo

DOI: 10.12659/MSM.952454

Med Sci Monit 2026; 32:e952454

0:00

In Press

Clinical Research  

Institutional and Regional Variations in Access to Clinical Trials and Next-Generation Sequencing in Turkis...

Med Sci Monit In Press; DOI: 10.12659/MSM.951027  

Clinical Research  

Low-Intensity Blood Flow-Restricted Multi-Joint Exercise Improves Muscle Function in Patients With Patellof...

Med Sci Monit In Press; DOI: 10.12659/MSM.950516  

Review article  

Musculoskeletal Ultrasound and MRI in the Evaluation of Chemotherapy-Induced Peripheral Neuropathy: A Review

Med Sci Monit In Press; DOI: 10.12659/MSM.951283  

Clinical Research  

Sensory Processing, Dissociation, and Affective Symptoms in Misophonia: A Cross-Sectional Study of 35 Adults

Med Sci Monit In Press; DOI: 10.12659/MSM.950938  

Most Viewed Current Articles

17 Jan 2024 : Review article   10,187,196

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,708,487

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,341,643

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   706,524

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750