The impact of capsulorhexis diameter, localization and shape on posterior capsule opacification

Ewa Langwinska- Wosko ACDEFG , Karina Broniek- Kowalik BCDEFG , Kamil Szulborski BCDEFG

DOI: 10.12659/MSM.881984

Med Sci Monit 2011; 17(10): CR577-582

0 Comments

Background

RISK FACTORS:

Several systemic and ocular associations have been cited as influencing the development of PCO. The incidence of PCO is more common in young patients and those with uveitis, pseudoexfoliation syndrome or traumatic cataracts. Myopic eyes have been postulated to increase the risk of PCO; this probably occurs because IOL implantation was deferred in them, but a study of IOL implantation in myopic eyes showed no association between the degree of myopia and the degree of PCO [4,6,7]. When compared with non-diabetic patients, diabetic patients had significantly more PCO following cataract surgery, but the stage of diabetic retinopathy and the systemic status of the diabetes does not seem to correlate with the degree of PCO [8]. Patients with retinitis pigmentosa showed a significantly higher incidence and density of PCO [9]. Patients with myotonic dystrophy required multiple capsulotomies following cataract surgery due to PCO and progressive capsulorhexis contracture [10].

Other factors that influence PCO development are: the intraocular lens type (material, design, optic size and edge, haptic design), accurate hydrodissection and removal of cortical masses, anterior capsule polishing, in-the-bag fixation of the optic and the haptic IOL part and anterior capsulorhexis localization and diameter. Numerous studies have examined the influence of physical properties of the IOL and accurate surgical lens removal technique on the formation of the PCO [11–19]. Relatively few studies have investigated the influence of anterior capsulorhexis on the development of posterior capsule opacification [20–22].

The present study evaluates the impact of anterior capsulorhexis diameter, localization and shape on PCO development following cataract extraction with phacoemulsification.

Material and Methods

This retrospective analysis reviewed 297 patients above age 45, randomly chosen from a group of 3500 operated patients who had undergone phacoemulsification and IOL implantation in the capsular bag at the Department of Ophthalmology, Medical University of Warsaw from September 2007 to September 2008. Inclusion criteria were used to define the presence of a senile cataract in an otherwise normal eye. Exclusion criteria consisted of: previous eye surgery and ocular or systemic diseases (eg, diabetes mellitus, rheumatoid diseases and serious cardiovascular diseases). Visual acuity, intraocular pressure (IOP), slit lamp examination, fundus examination, B-scan ultrasonography, keratometry, IOL power calculation with a biometry measurement and systemic examinations were all evaluated prior to surgery in all patients. All patients used 0.1% diclofenac sodium solution eye drops (Naclof; Novartis) 3 times on the day before surgery and on the day of surgery.

Surgical technique and medication were standardized. Phacoemulsification was performed by a single surgeon (E.L.-W.) under topical anesthesia. In the first group of 97 patients, 53 patients (55%) were postoperatively assigned to the group whose capsulorhexis were classified as small (3.9 to 4.9 mm in diameter) and 44 patients (45%) were assigned to the group whose capsulorhexis were classified as large (5.0 to 5.9 mm in diameter). The capsulorhexis were centrally located and regularly rimmed. Another group of 99 patients was postoperatively assigned into 1 of 2 subgroups – the first subgroup of 66 patients (66%) had capsulorhexis that were classified as centrally located and the second group consisted of 33 patients (34%) whose capsulorhexis were classified as paracentral. The capsulorhexis were defined as centrally located when the center of the capsulorhexis was in the center of the patient’s own lens and later in the center of the implanted posterior chamber intraocular lens (PCIOL). The capsulorhexis were defined as paracentral when the center of the capsulorhexis was not in the center of the patient’s own lens and the PCIOL. Capsulorhexis shift was at least 1.5 mm, which is half the radius of the optical part of implanted PCIOL. The capsulorhexis were small (3.9 to 4.9 mm in diameter) and regularly rimmed. A third group of 101 patients was also postoperatively assigned into 1 of 2 subgroups depending on the shape of their capsulorhexis rim. The first subgroup of 59 patients (58%) was classified as having a regularly rimmed capsulorhexis and the second subgroup of 42 patients (42%) was classified as having an irregularly rimmed capsulorhexis. The capsulorhexis were defined as regularly rimmed when the edge was smooth and the main perpendicular diameters were similar in length. The capsulorhexis were defined as irregularly rimmed when the edge was uneven at least on 1/3 of the capsulorhexis rim or the main perpendicular diameters were not similar in length. The capsulorhexis were small (3.9 to 4.9 mm in diameter) and centrally located.

The edge of the capsulorhexis had to lie completely on the intraocular lens optic for 360 degrees, even if it was eccentric, in all groups.

A 6.0-mm diameter optic, single-piece, hydrophobic acrylic intraocular lens (Alcon, model SA60AT) was implanted. Postoperatively, all patients used neomycin, polymyxin, and 0.1% dexamethasone solution eye drops (Maxitrol; Alcon Pharmaceuticals) 4 times a day for 1 month. Postoperative follow-up visits were performed on days 1, 3, 14, 30, 90, and 180. Patients were examined and refracted, and visual acuity was assessed using the Snellen chart. Digital retroillumination imaging of the posterior capsule through dilated pupils was performed with our high-resolution digitized camera system. Standardized retroillumination images of the posterior capsule were taken 14 and 180 days after the operation. The images taken after 180 days were used for image analysis.

At 6-month follow-up, posterior capsular opacification was classified as either none, mild, moderate, or severe, depending on the number of quadrants involved. Mild PCO was recognized when it was found in only 1 quadrant. Moderate PCO occurred when it was present in 2 quadrants, and severe PCO occurred when it was found in 3 or 4 quadrants. Special attention was given to central area as they are the most important to visual acuity.

The postoperative relationship of the anterior capsulorhexis margin to the intraocular lens optic was classified as central or paracentral. The capsulorhexis rim was defined as either a regular anterior capsulorhexis or an irregular anterior capsulorhexis.

Fisher’s exact test was used to analyze the difference in PCO between groups with a small and a large capsulorhexis, a central and a paracentral capsulorhexis, and regular and irregular capsulorhexis. PCO intensification was classed as either none, mild, moderate or severe. The Fisher-Freeman-Halton test and the Kruskal-Wallis test were used to analyze the difference in data between the groups with different capsulorhexis diameter, localization and shape. A P value of less than 0.001 was considered as statistically significant.

Before cataract extraction surgery all patients were adequately informed of the nature and possible consequences of the study and they provided signed consent for the use of medical records for research purposes.

Results

There were no surgical complications that would have led to patient exclusion. For 30 days after surgery, none of the patients reported infections, and within 180 days none of them had reported any serious fever episodes.

The mean age was 66 years (range: 45 to 87 years) (Figure 1); 188 of the patients were female and 109 were male. There were no significant differences in age and sex distribution between the groups.

Ninety-seven patients were postoperatively recruited and assigned to each capsulorhexis size group – 44 patients (45%) were found to have a large capsulorhexis and 53 patients (55%) were found to have a small capsulorhexis. In another group of 99 patients, it was the capsulorhexis localization that was assessed. In this group, 66 patients (66%) were found to have a central capsulorhexis and 33 patients (34%) were found to have a paracentral one. In the third group, which consisted of 101 patients, the shape of the capsulorhexis rim was assessed. The first subgroup of 59 patients (58%) were found to have regularly shaped capsulorhexis rims and 42 patients (42%) were found to have irregularly shaped rims.

At the 6-month follow-up, in the group in which the capsulorhexis diameter was observed, the edge of the large capsulorhexis lay at the edge of the intraocular lens optic in 19% (8 patients), while the rest of the patients had the edge of the anterior capsulorhexis on the intraocular lens optic for 360 degrees when the capsulorhexis was small as well as in large ones.

The amount of PCO at 6 months was significantly different between the groups with small and large capsulorhexis (Figure 2) – 86.79% of the patients with a small capsulorhexis had no or mild posterior capsule opacification, whereas 68.18% of the patients with a large capsulorhexis had moderate or severe PCO. Patients with a small capsulorhexis had significantly less posterior capsular opacification than those with a large capsulorhexis (p<0.001) (Table 1).

The amount of PCO in the groups with central (66 patients) and paracentral (33 patients) capsulorhexis localization was similar (Figure 3) – 89.4% of the patients with a central capsulorhexis had no or mild posterior capsule opacification, whereas 75.75% of the patients with a paracentral capsulorhexis had moderate or severe PCO. Patients with a central capsulorhexis had significantly less posterior capsular opacification than those with a paracentral anterior capsulorhexis (p<0.001) (Table 2).

Figure 4 shows the amount of PCO in the groups with regular and irregular anterior capsulorhexis rim shapes – 86.44% of the patients with a regular rim of the anterior capsulorhexis had no or mild posterior capsule opacification and 13.55% had moderate or severe PCO, while 69.04% of the patients with an irregular capsulorhexis rim had moderate or severe PCO. Patients with a regular anterior capsulorhexis rim had significantly less posterior capsular opacification than those with an irregular anterior capsulorhexis rim (p<0.001) (Table 3).

In all examined parameters the posterior capsule opacification ratio was smallest when the capsulorhexis was small, centrally located and with a regularly shaped rim when compared to the large, paracentral and irregular ones. There was no statistically significant difference in the Kruskal-Wallis test results between the groups with small, central and regular shape of capsulorhexis (p=0.6997) (Table 4).

In the group of all operated patients, 38 (12%) of those experiencing severe postoperative posterior capsule opacification qualified for a neodymium: yttrium-aluminium-garnet (Nd: YAG) laser posterior capsulotomy.

Discussion

The effect of the size of the capsulorhexis on posterior capsular opacification was investigated by Ravalico et al in a retrospective study of 107 patients who underwent extracapsular cataract extraction with capsulorhexis and capsular bag IOL implantation (polyHema IOLs and PMMA IOLs). They found that a capsulorhexis of a slightly smaller diameter than the IOL optic appears to be better than a large-size capsulorhexis in reducing the incidence of PCO [20]. Due to different cataract extraction procedures and IOL material, these results are not suitable for comparison with our research results.

A procedure similar to that used in our investigation was carried out by Hollic et al in a prospective study of 75 patients who underwent standardized phacoemulsification with capsulorhexis and in-the-bag placement of a 5.5-mm polymethylmethacrylate intraocular lens implant. The patients were randomly assigned to receive either a small capsulorhexis of 4.5 to 5 mm to lie completely on the intraocular lens optic, or a large capsulorhexis of 6 to 7 mm to lie completely off the lens optic. They suggested that large capsulorhexis were associated with a significant increase in the wrinkling of the posterior capsule and a worse posterior capsular opacification as compared to small capsulorhexis. At 1 year, the average percentage area of posterior capsular opacification was 32.7% for small capsulorhexis and 66.2% for large capsulorhexis. Patients with large capsulorhexis experienced significantly poorer visual acuities and a trend toward worse contrast sensitivities [21].

Aykan at al found comparable results in their prospective study (496 eyes underwent standardized phacoemulsification with capsulorhexis and capsular bag foldable acrylic IOL implantation). A small (4.5 to 5.0 mm) capsulorhexis and capsular bag implantation of 5.5 mm acrylic IOL reduced PCO incidence when compared to a 6.0 to 7.0 mm capsulorhexis [22].

The effect of the position of the anterior capsulorhexis on posterior capsular opacification was investigated by Wejde et al in a study of 119 patients who underwent cataract surgery with phacoemulsification performed by a single surgeon. The patients were randomized to implantation with either a silicone intraocular lens (IOL) (SI40NB, Allergan) or an AcrySof IOL (MA60BM, Alcon). Three years following the surgery, the rate of PCO was analyzed using the evaluation of posterior capsule opacification computer software (EPCO). The results were related to the capsulorhexis position, which was assessed with a retroillumination photograph. If the capsulorhexis was located partially or completely off the optics of the IOL as opposed to completely on the IOL, significantly more PCO was found, suggesting that the positioning of the capsulorhexis impacts the development of PCO [23].

Our results agree with earlier reports [21–23]. A relatively small and central capsulorhexis that allows the complete coverage of the IOL optics by the capsulorhexis edges seems to protect against PCO in cataract surgery. This may be explained by LEC mechanical blockade into the effect of the anterior lens capsule adhesion to the IOL, which is especially strong when there is complete anterior capsule overlap on the IOL optic in 360°.

However, Hayashi reported that in a study of 100 patients, 81% showed complete anterior capsule overlap, and there was no significant difference in the PCO value between the eyes with a complete anterior capsule overlap and those with partial or incomplete anterior capsule overlap. Furthermore, no significant correlation was found between the degree of the anterior capsule overlap and the extent of the PCO [24].

In our observations patients with a regularly shaped capsulorhexis rim had significantly less posterior capsular opacification than those with an irregular anterior capsulorhexis rim (p<0.001). We believe that when the capsulorhexis rim is regular, the disintegration of forces working on the lens capsule is identical, and wrinkling is much less likely to occur. In the event that the capsulorhexis rim is irregular, forces working on the lens capsule are different, which affects posterior capsular folds. This hypothesis needs to be confirmed by further studies. Statistical analysis with the Kruskal-Wallis test shows that there was no statistically significant difference between the groups with small, central or regularly shaped capsulorhexis (p=0.6997). This result shows that not only the diameter, but also the localization and the shape of the capsulorhexis has an influence on the occurrence of posterior capsular opacification, and that the degree of influence of these seems to be at a comparable level of importance.

Conclusions

This study indicates that not only a small capsulorhexis diameter, but also its central localization and its regular shape result in less posterior capsular opacification following the phacoemulsification procedure.

References

1. Birinci H, Kuruoglu S, Oge I, Effect of intraocular lens and anterior capsule opening type on posterior capsule opacification: J Cataract Refract Surg, 1999; 25; 1140-46, pmid: 10445202

2. Apple DJ, Solomon KD, Tetz MR, Posterior capsule opacification: Surv Ophthalmol, 1992; 37(2); 73-116, pmid: 1455302

3. Schmidbauer JM, Vargas LG, Apple DJ, Valuation of neodymium: yttrium-aluminum-garnet capsulotomies in eyes implanted with AcrySof intraocular lenses: Ophthalmology, 2002; 109(8); 1421, pmid: 12153790

4. Raj SM, Vasavada AR, Johar KS, Post-Operative Capsular Opacification: A Review: Int J Biomed Sci, 2007; 3(4); 237-50, pmid: 23675049

5. Werner L, Pandey SK, Apple DJ, Anterior capsule opacification: correlation of pathologic findings with clinical sequelae: Ophthalmology, 2001; 108(9); 1675, pmid: 11535472

6. Küchle M, Naumann G, Pseudoexfoliation and posterior capsular opacification: Am J Ophthalmol, 2001; 131(6); 820, pmid: 11398817

7. Lüke C, Dietlein TS, Jacobi PC, Massive anterior capsule shrinkage after plate-haptic silicone lens implantation in uveitis: J Cataract Refract Surg, 2001; 27(2); 333-36, pmid: 11226804

8. Hayashi Y, Kato S, Fukushima H, Relationship between anterior capsule contraction and posterior capsule opacification after cataract surgery in patients with diabetes mellitus: J Cataract Refract Surg, 2004; 30(7); 1517-20, pmid: 15210231

9. Sudhir RR, Rao SK, Capsulorhexis phimosis in retinitis pigmentosa despite capsular tension ring implantation: J Cataract Refract Surg, 2001; 27(10); 1691-94, pmid: 11687372

10. Gjertsen IK, Sandvig KU, Eide N, Olsen BA, Recurrence of secondary opacification and development of a dense posterior vitreous membrane in patients with myotonic dystrophy: J Cataract Refract Surg, 2003; 29; 213-16, pmid: 12551692

11. Abhilakh Missier KA, Nuijts RM, Tjia KF, Posterior capsule opacification: Silicone plate-haptic versus AcrySof intraocular lenses: J Cataract Refract Surg, 2003; 29(8); 1569-74, pmid: 12954308

12. Corydon C, Lindholt M, Knudsen EB, Capsulorhexis contraction after cataract surgery: Comparison of sharp anterior edge and modified anterior edge acrylic intraocular lenses: J Cataract Refract Surg, 2007; 33(5); 796-99, pmid: 17466850

13. Georgopoulos M, Menapace R, Findl O, After-cataract in adults with primary posterior capsulorhexis: comparison of hydrogel and silicone intraocular lenses with round edges after 2 years: J Cataract Refract Surg, 2003; 29(5); 955-60, pmid: 12781282

14. Gallagher SP, Pavilack MA, Risk factors for anterior capsule contraction syndrome with polypropylene or poly(methyl methacrylate) haptics: J Cataract Refract Surg, 1999; 25(10); 1356-61, pmid: 10511935

15. Tadros A, Bhatt UK, Karim MN, Removal of lens epithelial cells and the effect on capsulorhexis size: J Cataract Refract Surg, 2005; 31(8); 1569-74, pmid: 16129293

16. Hanson RJ, Rubinstein A, Sarangapani S, Effect of lens epithelial cell aspiration on postoperative capsulorhexis contraction with the use of the AcrySof intraocular lens: Randomized clinical trial: J Cataract Refract Surg, 2006; 32(10); 1621-26, pmid: 17010857

17. Menapace R, Routine posterior optic buttonholing for eradication of posterior capsule opacification in adults. Report of 500 consecutive cases: J Cataract Refract Surg, 2006; 32; 929-43, pmid: 16814050

18. Ronbeck M, Zetterstrom Ch, Wejde G, Kugelberg M, Comparison of posterior capsule opacification development with 3 intraocular lens types: J Cataract Refract Surg, 2009; 35; 1935-40, pmid: 19878826

19. Nixon DR, Woodcock MG, Pattern of posterior capsule opacification models 2 years postoperatively with 2 single-piece acrylic intraocular lenses: J Cataract Refract Surg, 2010; 36; 929-34, pmid: 20494763

20. Ravalico G, Tognetto D, Palomba M, Capsulorhexis size and posterior capsule opacification: J Cataract Refract Surg, 1996; 22(1); 98-103, pmid: 8656372

21. Hollick EJ, Spalton DJ, Meacock WR, The effect of capsulorhexis size on posterior capsular opacification: One-year results of a randomized prospective trial: Am J Ophthalmol, 1999; 128(3); 271-79, pmid: 10511019

22. Aykan U, Bilge AH, Karadayi K, Akin T, The effect of capsulorhexis size on development of posterior capsule opacification: small (4.5 to 5.0 mm) versus large (6.0 to 7.0 mm): Eur J Ophthalmol, 2003; 13(6); 541-45, pmid: 12948312

23. Wejde G, Kugelberg M, Zetterström C, Position of anterior capsulorhexis and posterior capsule opacification: Acta Ophthalmol Scand, 2004; 82; 531-34, pmid: 15453848

24. Hayashi K, Hayashi H, Influence on Posterior Capsule Opacification and Visual Function of Intraocular Lens Optic Material: Am J Ophthalmol, 2007; 144; 195-202, pmid: 17553447

In Press

Clinical Research  

Institutional and Regional Variations in Access to Clinical Trials and Next-Generation Sequencing in Turkis...

Med Sci Monit In Press; DOI: 10.12659/MSM.951027  

Clinical Research  

Low-Intensity Blood Flow-Restricted Multi-Joint Exercise Improves Muscle Function in Patients With Patellof...

Med Sci Monit In Press; DOI: 10.12659/MSM.950516  

Review article  

Musculoskeletal Ultrasound and MRI in the Evaluation of Chemotherapy-Induced Peripheral Neuropathy: A Review

Med Sci Monit In Press; DOI: 10.12659/MSM.951283  

Clinical Research  

Sensory Processing, Dissociation, and Affective Symptoms in Misophonia: A Cross-Sectional Study of 35 Adults

Med Sci Monit In Press; DOI: 10.12659/MSM.950938  

Most Viewed Current Articles

17 Jan 2024 : Review article   10,187,196

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,708,487

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,341,643

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   706,524

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750