Cranioplasty prosthesis manufacturing based on reverse engineering technology

Robert Chrzan ABCEF , Andrzej Urbanik ABCEFG , Krzysztof Karbowski ABCF , Marek Moskała ABCF , Jarosław Polak ABCF , Marek Pyrich ABCF

DOI: 10.12659/MSM.882186

Med Sci Monit 2012; 18(1): MT1-6

0 Comments

Background

Most patients with large focal skull bone loss after craniectomy are then referred for a cranioplasty. This procedure is performed not only for aesthetic reasons, but also to protect underlying neural tissue [1,2] and improve its perfusion and metabolism [3–6].

Various materials are used, including autograft, allograft or xenograft bone [7,8], metals [9,10] and nonmetallic bone substitutes.

The autograft bone flap obtained during the initial craniectomy may be stored either fresh-frozen [7], which is the preferred method, or in the abdominal wall [11].

However, in many cases this is impossible because of bone destruction after trauma or inflammation.

Metals, like titanium, cause artifacts in CT and MR examinations, limiting the value of follow-up studies; other metals, like ferromagnetic materials, even preclude performing MR.

At present, the use of synthetic materials is more common (eg, polymethyl methacrylate (PMMA) [12,13], PMMA mixed with hydroxyapatite [14], carbon fiber-reinforced plastics (CFRP) [15], knitted polypropylene-polyester [16]).

In many cases, a bone defect has a complicated shape and different curvatures in various planes. A prosthesis must, therefore, be individually adjusted by a neurosurgeon during the surgery, which increases operating time, blood loss and infection risk [12].

Reverse engineering is a form of technology which creates a computer-aided design (CAD) model of a real structure. In medicine, virtual models of body parts may be produced using data obtained from imaging modalities like CT or MR.

Rapid prototyping, in turn, is a form of technology which produces physical objects from virtual CAD models, particularly those previously obtained using reverse engineering.

Such technologies may help obtain an individually adjusted prosthesis for cranioplasty [17–23] before the surgery, reducing the above-mentioned problems.

The aim of this study was to assess the clinical usefulness of reverse engineering and rapid prototyping in cranioplasty prosthesis manufacturing by comparing the mean operating time in the group of patients with individually-adjusted, preoperative prosthesis based on CT data with that of the control group of patients who had a prosthesis adjusted manually to the full extent during the surgery.

Material and Methods

PATIENTS:

CT (Figure 1) was performed on 19 patients with focal skull bone loss after craniectomy (12 men, 7 women, 21 to 54 years old) in the Department of Radiology of the Cracow University Hospital using a 16-row scanner Somatom Sensation 16 (Siemens Healthcare, Erlangen, Germany).The patients were included into the study during the years 2008–2010 and were randomly selected by neurosurgeons from the group of patients referred for cranioplasty.

We used a dedicated CT protocol (collimation 0.75 mm, slice thickness 0.75 mm, reconstruction increment 0.5 mm, sharp kernel H60s, reconstruction FOV adjusted to the bone defect size) to get the highest spatial resolution possible.

In the control group of 20 patients with focal skull bone loss after craniectomy (14 men, 6 women, 18–60 years of age, included into the study during the years 2008–2010), a prosthesis was individually adjusted by a neurosurgeon during the surgery, without using CT-based reverse engineering/rapid prototyping.

Informed consent was obtained from each patient in the study after the nature of the procedure had been fully explained. The protocol was approved by an institutional review board.

CRANIOPLASTY PROSTHESIS:

The main problem in the subsequent creation of a virtual 3D model was the proper assessment of bone edges. The commonly-used computer method of edge detection is based on a threshold value, arbitrarily selected by the user to discriminate between bone and other structures. However, the bone thickness is large enough to create partial volume artifacts and generate important errors in edge detection.

Therefore, specific software was created at the Cracow University of Technology for edge detection using a luminance analysis method (Figure 2), which significantly reduced the edge detection errors.

Then, in each case, a virtual model of the skull (Figure 3), based on CT data, was generated using CAD software CATIA (Dassault Systèmes, Vélizy-Villacoublay, France).

Such a model was the basis for designing the cranioplasty prosthesis.

For the prosthesis we used a knitted polypropylene-polyester material called Codubix by Tricomed, which is the most popular in Poland (Figure 4).

In the afore-mentioned group of 19 patients, we tested 2 ways of obtaining individually adjusted prosthesis.

In 10 patients a material model of the focal skull bone deficit (Figure 5) was produced, using Computer Numerical Control (CNC) Milling Arrow 500 (Cincinnati Milacron, Cincinnati, Ohio, USA) and polyurethane resin Prolab 60 (Axon Technologies, Cergy Cedex, France). This model was then used by a neurosurgeon for the individual adjustment of a prosthesis before surgery (Figure 6). The adjusted prosthesis was sterilized before implantation.

In 9 patients with more complicated bone deficits (different curvatures in various planes, preventing the use of an adjusted universal prosthesis), apart from the material model of bone deficit as above, a material form to profile the prosthesis was produced (Figure 7) using the same method and aluminum-silicon alloy PA6. The manufacturer, using the form, delivered the already-sterilized prosthesis with proper curvatures and margins adjusted.

IMPLANTATION:

In each case, the prosthesis was implanted into the patient during neurosurgery in the Neurosurgery and Neurotraumatology Department of Cracow University Hospital (Figures 8, 9).

DATA ANALYSIS:

We compared the mean operating time in the group of 19 patients with reverse engineering/rapid prototyping-based cranioplasty with that of the control group of 20 patients.

In the statistical analysis we used the Shapiro-Wilk normality test, Levene’s homogeneity of variance test and Student’s independent 2-sample T test.

Results

In the group of 19 patients with reverse engineering/rapid prototyping-based cranioplasty, the mean operating time was 120.3 minutes (minimum 110 minutes, maximum 140 minutes, SD 7.9 minutes).

In the control group of 20 patients, the mean operating time was 136.5 minutes (minimum 120 minutes, maximum. 150 minutes, SD 10.5 minutes).

In both groups, normal distribution was confirmed using the Shapiro-Wilk test (p>0.05) and homogeneity of variance was found using Levene’s test (p>0.05), so Student’s T test could be used. The difference between the mean values in the groups examined was found to be statistically significant (t=–5.43, p=0.000004).

The neurosurgeons found reverse engineering/rapid prototyping-based cranioplasty particularly useful in more complicated bone deficits, with different curvatures in various planes. In their opinion, in such cases individually-adjusted prostheses resulted in a much better cosmetic effect, mainly because of accurate skull symmetry achieved.

Discussion

Until now the universal prosthesis for cranioplasty was manually adjusted to a skull bone defect by a surgeon during the operation. This was a universal prosthesis which, unfortunately, meant that in many cases its fit was not good enough. In some cases, a surgeon even had to start with another prosthesis because of excessive cutting during the manual adjustment. It could thus unnecessarily extend the operation time.

After the application of reverse engineering technology to properly adjust the prosthesis before the surgery, the time needed for the operation was substantially reduced.

This has already been reported by other authors.

Lee et al. [12] compared 3 groups of cranioplasty patients: group 1 (91 patients) receiving fresh frozen autograft bone, group 2 (23 patients) with PMMA prosthesis molded intra-operatively, and group 3 (17 patients) receiving a custom-made prefabricated PMMA prosthesis manufactured based on CT exam. Group 2 patients required significantly more operating time than both group 1 and group 3 patients, but the operating time did not differ significantly between groups 1 and 3. Mean intra-operative blood loss was significantly higher in group 2 than in group 1, but did not differ significantly between group 1 and group 3. The infection rate in group 3 was lower than that in group 2 and was comparable to that of group 1.

D’Urso et al. [22] used CT data and stereolithography (SL) technology to manufacture cranioplasty acrylic implants in 30 patients. Such customized implants reduced operating time, afforded excellent cosmesis and were cost-effective. The patients reported that the opportunity to see the biomodel and implant preoperatively improved their understanding of the procedure.

In our study the neurosurgeons found reverse engineering/rapid prototyping-based cranioplasty particularly useful in more complicated bone deficits. Individually prefabricated and profiled prostheses were much better fitted in patients with different curvatures in various planes, resulting in a much better cosmetic effect.

Dean et al. [24], using CT data for manufacturing PMMA or pre-bent titanium cranioplasty implants, also found them to be better fitting and more cosmetically suitable compared to manually prepared implants. They also concluded that such well-fitting implants were more likely to protect the brain from trauma and infection.

According to Goh et al. [25], using customized implants fabricated by computer-aided design helps to avoid unsatisfactory outcomes of the surgery and should be the preferred method in patients after previously failed cranioplasty.

The additional cost of manufacturing the rapid prototyping model in our research was about $300. It is difficult to directly compare it with the other authors’ values (for example approximately $1300 per case in D’Urso’s [22] research) because of the different techniques used. However, some authors have investigated some feasible technical solutions for minimizing the implant cost based on the availability of production technologies in a region. Hieu et al. [26] used CNC milling techniques for making molds to fabricate PMMA implants and found the cost acceptable for the Association of South-East Asian Nations (ASEAN) region.

The future application of computer-aided systems for cranioplasty will probably not be limited to customized implant fabrication. In patients with skull bone tumors, the robot-guided bone resection based on CT data will be possible. Weihe et al. [27] constructed a prototype system of single-step skull bone resection and reconstruction based on CT data and tested it on an animal cadaver model.

Finally, it should be emphasized that reverse engineering and rapid prototyping technologies may be helpful not only in cranioplasty but also in many other surgical reconstruction procedures, including craniofacial bones [28].

Conclusions

Reverse engineering and rapid prototyping may reduce the time needed for cranioplasty neurosurgery and improve the fitting of the prosthesis.

Such technologies may utilize data obtained by commonly used spiral CT scanners.

The manufacturing of individually-adjusted prostheses using reverse engineering and rapid prototyping technologies should be commonly used in patients planned for cranioplasty with synthetic material.

References

1. Sanan A, Haines SJ, Repairing holes in the head: a history of cranioplasty: Neurosurgery, 1997; 40; 588-603, pmid: 9055300

2. Dujovny M, Aviles A, Agner C, Cranioplasty: cosmetic or therapeutic?: Surg Neurol, 1997; 47; 238-41, pmid: 9068693

3. Winkler PA, Stummer W, Linke R, Influence of cranioplasty on postural blood flow regulation, cerebrovascular reserve capacity, and cerebral glucose metabolism: J Neurosurg, 2000; 93; 53-61, pmid: 10883905

4. Kuo JR, Wang CC, Chio CC, Neurological improvement after cranioplasty – analysis by transcranial Doppler ultrasonography: J Clin Neurosci, 2004; 11; 486-89, pmid: 15177389

5. Isago T, Nozaki M, Kikuchi Y, Sinking skin flap syndrome. A case of improved cerebral blood flow after cranioplasty: Ann Plast Surg, 2004; 53; 288-92, pmid: 15480019

6. Sakamoto S, Eguchi K, Kiura Y, CT perfusion imaging in the syndrome of the sinking skin flap before and after cranioplasty: Clin Neurol Neurosurg, 2006; 108; 583-85, pmid: 15921849

7. Iwama T, Yamada J, Imai S, The use of frozen autogenous bone flaps in delayed cranioplasty revisited: Neurosurgery, 2003; 52; 591-95, pmid: 12590683

8. Taggard DA, Menezes AH, Successful use of rib grafts for cranioplasty in children: Pediatr Neurosurg, 2001; 34; 149-55, pmid: 11359103

9. Joffe J, Harris M, Kahugu F, A prospective study of computer-aided design and manufacture of titanium plate for cranioplasty and its clinical outcome: Brit J Neurosurg, 1999; 13; 576-80, pmid: 10715726

10. Joffe JM, Nicoll SR, Richards R, Validation of computer assisted manufacture of titanium plates for cranioplasty: Int J Oral Maxillofac Surg, 1999; 28; 309-13, pmid: 10416902

11. Movassaghi K, Ver Halen J, Ganchi P, Cranioplasty with subcutaneously preserved autologous bone grafts: Plast Reconstr Surg, 2006; 117; 202-6, pmid: 16404268

12. Lee SC, Wu CT, Lee ST, Cranioplasty using polymethyl methacrylate prostheses: J Clin Neurosci, 2009; 16; 56-63, pmid: 19046734

13. Fathi AR, Marbacher S, Lukes A, Cost-effective patient-specific intraoperative molded cranioplasty: J Craniofac Surg, 2008; 19; 777-81, pmid: 18520398

14. Rotaru H, Baciut M, Stan H, Silicone rubber mould cast polyethylmethacrylate-hydroxyapatite plate used for repairing a large skull defect: J Craniomaxillofac Surg, 2006; 34; 242-46, pmid: 16644233

15. Saringer W, Nöbauer-Huhmann I, Knosp E, Cranioplasty with individual carbon fibre reinforced polymere (CFRP) medical grade implants based on CAD/CAM technique: Acta Neurochir (Wien), 2002; 144; 1193-203, pmid: 12434176

16. Andrzejak S, Fortuniak J, Wróbel-Wiśniewska G, Clinical evaluation of the polypropylene-polyester knit used as a cranioplasty material: Acta Neurochir (Wien), 2005; 147; 973-76, pmid: 16028110

17. Solaro P, Pierangeli E, Pizzoni C, From computerized tomography data processing to rapid manufacturing of custom-made prostheses for cranioplasty. Case report: J Neurosurg Sci, 2008; 52; 113-16, pmid: 18981986

18. Maravelakis E, David K, Antoniadis A, Reverse engineering techniques for cranioplasty: a case study: J Med Eng Technol, 2008; 32; 115-21, pmid: 17852651

19. Hoffmann B, Sepehrnia A, Taylored implants for alloplastic cranioplasty – clinical and surgical considerations: Acta Neurochir Suppl, 2005; 93; 127-29, pmid: 15986741

20. Wulf J, Busch LC, Golz T, CAD generated mold for preoperative implant fabrication in cranioplasty: Stud Health Technol Inform, 2005; 111; 608-10, pmid: 15718807

21. Müller A, Krishnan KG, Uhl E, The application of rapid prototyping techniques in cranial reconstruction and preoperative planning in neurosurgery: J Craniofac Surg, 2003; 14; 899-914, pmid: 14600634

22. D’Urso PS, Earwaker WJ, Barker TM, Custom cranioplasty using stereolithography and acrylic: Br J Plast Surg, 2000; 53; 200-4, pmid: 10738323

23. Agner C, Dujovny M, Evenhouse R, Stereolithography for posterior fossa cranioplasty: Skull Base Surg, 1998; 8; 81-86, pmid: 17171056

24. Dean D, Min KJ, Bond A, Computer aided design of large-format prefabricated cranial plates: J Craniofac Surg, 2003; 14; 819-32, pmid: 14600623

25. Goh RC, Chang CN, Lin CL, Customised fabricated implants after previous failed cranioplasty: J Plast Reconstr Aesthet Surg, 2010; 63; 1479-84, pmid: 19766072

26. Hieu LC, Bohez E, Sloten J, Design and manufacturing of cranioplasty implants by 3-axis cnc milling: Technol Health Care, 2002; 10; 413-23, pmid: 12368561

27. Weihe S, Schiller C, Rasche C, CAD/CAM prefabricated individual skull implants: new aspects in robot resection and guided bone regeneration: International Congress Series, 2004; 1268; 584-90

28. Elgalal M, Kozakiewicz M, Loba P, Patient specific implants, designed using Rapid Prototyping and diagnostic imaging, for the repair of orbital fractures: Med Sci Monit, 2010; 16(Suppl 1); 75-79

In Press

Clinical Research  

Institutional and Regional Variations in Access to Clinical Trials and Next-Generation Sequencing in Turkis...

Med Sci Monit In Press; DOI: 10.12659/MSM.951027  

Clinical Research  

Low-Intensity Blood Flow-Restricted Multi-Joint Exercise Improves Muscle Function in Patients With Patellof...

Med Sci Monit In Press; DOI: 10.12659/MSM.950516  

Review article  

Musculoskeletal Ultrasound and MRI in the Evaluation of Chemotherapy-Induced Peripheral Neuropathy: A Review

Med Sci Monit In Press; DOI: 10.12659/MSM.951283  

Clinical Research  

Sensory Processing, Dissociation, and Affective Symptoms in Misophonia: A Cross-Sectional Study of 35 Adults

Med Sci Monit In Press; DOI: 10.12659/MSM.950938  

Most Viewed Current Articles

17 Jan 2024 : Review article   10,187,196

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,708,487

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,341,643

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   706,524

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750