28 July 2003
Annual radiation background in the City of Isfahan
Mohammad Bagher TavakoliMed Sci Monit 2003; 9(7): PH7-10 :: ID: 13076
Abstract
Background:Measurement of environmental exposure is very important from different points of view especially for human health. In Iran, it is measured in some cities especially in high background areas such as Ramsar, but so far there is not any measurement in Isfahan.Material/Methods:Measurements were performed using CaSO4: Dy TLDs. The locations under investigations were 52 health centers distributed all around Isfahan city. Each TLD badge was put in a special plastic bag and left over the roofs of the selected health center for a month. The procedure was repeated for all 12 months of the year 1379 (21st March 2000 to 20th March 2001).Results:The maximum and the minimum of obtained results for dose equivalent in different months and locations were 15.9i10–2 and 6.5i10–2 mSv. Obtained maximum and minimum of the means between all the locations were 10.5i10–2 and 8.6i102 mSv for the whole year. Monthly mean and SD for Isfahan city for the whole year were 9.7i10–2 and 1.5i10–2 respectively therefore mean annual dose equivalent in Isfahan city is 1.16I0.18 mSv. The results do not show any high background radiation area.Conclusions:From the total of 624 measurements at 52 sites of Isfahan, obtained annual outdoor X and gamma ray dose equivalent for a person living in isfahan is 1.16I0.18 mSv. This figure is about 48.3% of the world average total radiation background reported by UNSCEAR.
Keywords: Background Radiation, Cities, Environmental Exposure, Gamma Rays, Iran, Periodicity, Radiation Monitoring, X-Rays
Editorial
01 January 2026 : Editorial
Editorial: Increasing Awareness of Lung Cancer in Non-Smokers and Never-Smokers Challenges Current Approaches to Prevention and ScreeningDOI: 10.12659/MSM.952454
Med Sci Monit 2026; 32:e952454
In Press
Clinical Research
Institutional and Regional Variations in Access to Clinical Trials and Next-Generation Sequencing in Turkis...Med Sci Monit In Press; DOI: 10.12659/MSM.951027
Clinical Research
Low-Intensity Blood Flow-Restricted Multi-Joint Exercise Improves Muscle Function in Patients With Patellof...Med Sci Monit In Press; DOI: 10.12659/MSM.950516
Review article
Musculoskeletal Ultrasound and MRI in the Evaluation of Chemotherapy-Induced Peripheral Neuropathy: A ReviewMed Sci Monit In Press; DOI: 10.12659/MSM.951283
Clinical Research
Sensory Processing, Dissociation, and Affective Symptoms in Misophonia: A Cross-Sectional Study of 35 AdultsMed Sci Monit In Press; DOI: 10.12659/MSM.950938
Most Viewed Current Articles
17 Jan 2024 : Review article 10,187,196
Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron VariantDOI :10.12659/MSM.942799
Med Sci Monit 2024; 30:e942799
13 Nov 2021 : Clinical Research 3,708,487
Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...DOI :10.12659/MSM.932788
Med Sci Monit 2021; 27:e932788
14 Dec 2022 : Clinical Research 2,341,643
Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase LevelsDOI :10.12659/MSM.937990
Med Sci Monit 2022; 28:e937990
16 May 2023 : Clinical Research 706,524
Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...DOI :10.12659/MSM.940387
Med Sci Monit 2023; 29:e940387