Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

01 January 1998

Non-invasive detection of intracranial vascular pathologies

Wojciech Muliński, Witold Wierzejewski, Tomasz Gierczak

Med Sci Monit 1998; 4(1): MT176-181 :: ID: 502857

Abstract

Cerebral vessel deformations generate acoustical bruits due to the disturbance in laminar blood flow. Signals of a characteristic spectral shape are produced by aneurysm, arteriovenous malformation and stenotic narrowing.These acoustical signals are strongly attenuated during propagation through the cranium and become very weak and noisy when outside the skull. A newly designed, highly sensitive accelerometric microphone, a low noise amplifier and a filter unit allow for the detection of very weak (low acoustical level) periodical signals in the 200Hz to 1000Hz span. Signals generated from pathological vessels have peaks in the spectrum at an acoustical level below OdB SPL (Sound Pressure Level). There are also acoustical bruits at much lower levels, which probably owe physiologically originated. Signal control and processing, implemented in the microcomputer software, performs a screening and non-invasive method for early detection of cerebral vessel deformations.

Keywords: Aneurysm, cerebral vessels deformations

Add Comment 0 Comments

Editorial

01 December 2024 : Editorial  

Editorial: The 2024 Revision of the Declaration of Helsinki and its Continued Role as a Code of Ethics to Guide Medical Research

Dinah V. Parums

DOI: 10.12659/MSM.947428

Med Sci Monit 2024; 30:e947428

0:00

In Press

Animal Research  

Histological Evaluation of the Effects of Intra-Articular Injection of Caffeic Acid on Cartilage Repair in ...

Med Sci Monit In Press; DOI: 10.12659/MSM.946845  

Clinical Research  

Impact of Clear Aligners vs Conventional Brackets on Oxidant and Antioxidant Levels: A Case-Control Study

Med Sci Monit In Press; DOI: 10.12659/MSM.946419  

Animal Research  

Accuracy of 3 Intraoral Scanners in Recording Impressions for Full Arch Dental Implant-Supported Prosthesis...

Med Sci Monit In Press; DOI: 10.12659/MSM.946624  

Clinical Research  

Shiga Toxin-Producing E. coli and Hemolytic Uremic Syndrome: A Study of the 2022 Outbreak in Turkey

Med Sci Monit In Press; DOI: 10.12659/MSM.946033  

Most Viewed Current Articles

17 Jan 2024 : Review article   6,956,586

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

14 Dec 2022 : Clinical Research   1,961,734

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   696,847

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

07 Jan 2022 : Meta-Analysis   262,907

Efficacy and Safety of Light Therapy as a Home Treatment for Motor and Non-Motor Symptoms of Parkinson Dise...

DOI :10.12659/MSM.935074

Med Sci Monit 2022; 28:e935074

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750