Analysis of in vivo 1H MR spectra of normal brain tissue by means of second derivative method
Maria SokółMed Sci Monit 2001; 7(3): MT496-503 :: ID: 510349
Abstract
Background: As follows from comparative studies conducted in a number of centres, meeting the repeatability and reliability conditions in MRS in vivo measurements depends mainly on system stability and operator-related external factors. The aim of the study was to check the usefulness of the automated fitting method offered by PeakFit 4.0 (by SPSS Inc., Chicago, USA).
Material/Methods: Short echo time in vivo PRESS 1H MR spectra (2T, TE=35 ms) of normal brain were fitted in the frequency domain using the second derivative method. In this approach local maxima and hidden peaks are found as local minima of spectrum second derivative. The Lorentzian robust minimization procedure using Levenburg-Marquardt non-linear fitting engine was applied. Spectral lines were approximated under the assumption of the mixed Lorentzian/Gaussian lineshapes. The same procedure was applied to 18 proton spectra recorded from frontal lobe white matter.
Results: The number of peaks found within the range of 0.74&dw kreska;4.2 ppm was 52&plusm;3 and their positions were almost the same. The fitted lines were assigned on the basis of the J-pattern recalculated for the field strength of 2T and by comparing the chemical shifts with the shifts in single compound spectra. The ratios of main metabolites, such as NAA/Cr, Cho/Cr, Cho/NAA and mI/Cr, are in accordance with those obtained previously using the software supplied with the MR imager and the absolute concentrations of NAA, Cho, mI, Glc and Glu obtained from the fit agree with those reported in literature which confirms the usefulness of the second derivative method in routine analyses of 1H MR brain spectra.
Conclusions: The automated fitting enables reasonable metabolite ratios and absolute concentrations to be obtained, however it should be kept in mind that the second derivative follows only the shape of the curve that represents the sum of all metabolites.
Keywords: in vivo 1H MRS, spectra fitting, second derivative method, metabolite concentrations
Editorial
01 December 2024 : Editorial
Editorial: The 2024 Revision of the Declaration of Helsinki and its Continued Role as a Code of Ethics to Guide Medical ResearchDOI: 10.12659/MSM.947428
Med Sci Monit 2024; 30:e947428
In Press
Animal Research
Histological Evaluation of the Effects of Intra-Articular Injection of Caffeic Acid on Cartilage Repair in ...Med Sci Monit In Press; DOI: 10.12659/MSM.946845
Clinical Research
Impact of Clear Aligners vs Conventional Brackets on Oxidant and Antioxidant Levels: A Case-Control StudyMed Sci Monit In Press; DOI: 10.12659/MSM.946419
Animal Research
Accuracy of 3 Intraoral Scanners in Recording Impressions for Full Arch Dental Implant-Supported Prosthesis...Med Sci Monit In Press; DOI: 10.12659/MSM.946624
Clinical Research
Shiga Toxin-Producing E. coli and Hemolytic Uremic Syndrome: A Study of the 2022 Outbreak in TurkeyMed Sci Monit In Press; DOI: 10.12659/MSM.946033
Most Viewed Current Articles
17 Jan 2024 : Review article 6,956,586
Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron VariantDOI :10.12659/MSM.942799
Med Sci Monit 2024; 30:e942799
14 Dec 2022 : Clinical Research 1,961,734
Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase LevelsDOI :10.12659/MSM.937990
Med Sci Monit 2022; 28:e937990
16 May 2023 : Clinical Research 696,847
Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...DOI :10.12659/MSM.940387
Med Sci Monit 2023; 29:e940387
07 Jan 2022 : Meta-Analysis 262,907
Efficacy and Safety of Light Therapy as a Home Treatment for Motor and Non-Motor Symptoms of Parkinson Dise...DOI :10.12659/MSM.935074
Med Sci Monit 2022; 28:e935074