BT-online: an innovated and promising computer assisted transfusion system

Idil YENİCESUABCDEFG, Günter DilsizBCDEF, Gülsan SucakDE, Zeynep AkıF

Med Sci Monit 2008; 14(8): MT21-26 :: ID: 865800

Abstract

Background
Errors in the transfusion process are common. These errors encompass a spectrum of events ranging from incorrect transfusion to administration of infected blood products. To overcome these complications, we developed a new blood management software system - the BT-Online system - to decrease erroneous transfusions that are mostly human based.
Material and Method
Like previously developed transfusion safety systems, this program uses handheld devices to improve the safety of bedside practices. The BT-online system consists of 3 main structures: (1) the personal digital assistant, (2) the equipment and software (user interface), and (3) the relational database and a web service providing communication of a security-layered database with other personal digital assistants.
Results
This system has many features including the ability at the bedside to check the complete patient history and requested tests and blood products, the ability to conduct simultaneous multiple procedures, the ability to transmit results to the database, the ability to gather restrictions and warnings regarding the transfusion and request sections, the ability to provide constant and secure data transfer, a user-friendly design, the ability to gather warnings during measurements that alert the user to potential errors, the ability to enter complications and symptoms and retrieve relevant information and suggestions, the ability to enter transfusion complications, and the ability to check test results and create statistical data for future use.
Conclusions
This system can contribute to blood banks and health care facilities via the above-mentioned specifications. We recommend this system to health care facilities with a significant patient turnover.

Keywords: Medical Records Systems, Computerized - instrumentation, Online Systems, Software, Blood Transfusion - methods

Add Comment 0 Comments

Editorial

01 July 2026 : Editorial  

Editorial: The WHO Identifies Ebola Disease Due to Bundibugyo Virus as a Public Health Emergency of International Concern (PHEIC) as Vaccine Development Accelerates

Dinah V. Parums ORCID logo

DOI: 10.12659/MSM.954627

Med Sci Monit 2026; 32:e954627

0:00

In Press

Clinical Research  

Comparative Effectiveness of a Nurse-Led Care Model vs Usual Care in Rheumatoid Arthritis: A Longitudinal C...

Med Sci Monit In Press; DOI: 10.12659/MSM.953211  

Clinical Research  

Impact of Treatment Modality on Pain, Sexual Function, and Psychological Well-Being in Patients With Bartho...

Med Sci Monit In Press; DOI: 10.12659/MSM.952422  

Clinical Research  

Association Between Radiographic Knee Osteoarthritis, Pre-Fracture Mobility, and Hip Fracture Patterns in O...

Med Sci Monit In Press; DOI: 10.12659/MSM.952678  

Clinical Research  

Association Between Total Cholesterol–to–High-Density Lipoprotein Ratio and Gestational Hypertension: A Cas...

Med Sci Monit In Press; DOI: 10.12659/MSM.952395  

Most Viewed Current Articles

17 Jan 2024 : Review article   14,176,084

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,757,530

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,466,116

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   708,768

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750